Ovine panel reactive antibody assay of HLA responsivity to allograft bioengineered vascular scaffolds.
نویسندگان
چکیده
BACKGROUND Increasing evidence implicates immune response as a contributing factor in the failure of allograft valve transplants. Increases in panel reactive antibodies have been identified in human subjects. To correlate these responses with novel preimplantation processing methods to reduce cellularity, both a relevant panel reactive antibody assay and a chronic implantation animal model are necessary. We modified a human flow cytometric panel reactive antibody assay for ovine model use to detect antibody responses to residual antigen-loading decellularized scaffolds engineered from pulmonary artery tissue. METHODS A clinical panel reactive antibody assay was modified with anti-sheep antibodies. Dimethyl sulfoxide cryopreserved (n = 4) and decellularized scaffolds (n = 8) fashioned as patches from pulmonary arteries were implanted for study. Fresh (nonprocessed) tissue implants were used as positive controls (n = 2), and sham-treated animals were used as negative controls (n = 2). Baseline, 10-week, and 20-week blood samples were assayed for panel reactive antibody levels. Immunohistochemistry with anti-major histocompatibility complex antibodies were performed on preimplantation scaffolds. RESULTS Chronic implants of fresh tissue stimulated strong panel reactive antibody responses. Classically cryopreserved tissues provoked modest panel reactive antibody responses to major histocompatibility complex I antigen and no response to major histocompatibility complex II antigen. Decellularized tissue scaffolds provoked minimal to no panel reactive antibody responses to either major histocompatibility complex I or II antigen. Immunohistochemistry correlated with the panel reactive antibody results by identifying significant amounts of major histocompatibility complex I and II in fresh tissue, reduced antigen staining in cryopreserved control tissues, and minimal amounts in decellularized tissues. CONCLUSIONS These studies with an ovine modified panel reactive antibody assay confirmed minimal immune allosensitization to transplanted decellularized tissue patches. Qualifying criteria for putative tissue-engineered scaffolds should include minimal recipient panel reactive antibody response.
منابع مشابه
Donor-specific HLA class I and CREG antibodies in complement-dependent cytotoxicity-negative renal transplants.
Development of a solid-phase, single antigen panel reactive antibody test (SA-PRA) permits the analysis of antibody specificities. This study determined the impact of donor-specific antibodies (DSA) against class I HLA private antigens (DS-HLA) or HLA-A and -B cross-reactive group (DS-CREG) in kidney transplantation. Pre- and post-transplant sera of 133 renal allograft patients who had negative...
متن کاملEffects of recombinant human erythropoietin on HLA sensitization and cell mediated immunity.
Highly presensitized patients wait longer for a renal allograft than unsensitized patients and have a poorer allograft survival rate. Repeated blood transfusions have been implicated in the induction and maintenance of sensitization. To determine the effect of recombinant human erythropoietin (rHuEPO) therapy on five transfusion dependent, highly sensitized adolescents on dialysis, we serially ...
متن کاملAnti-HLA Antibodies and Kidney Allograft Outcomes in Recipients with Donor Bone Marrow Cell Infusion
Background: Anti-HLA-antibodies are known to affect the allograft survival in transplant recipient patients. Objective: The aim of this study was to evaluate the association between anti-HLA antibodies and kidney allograft outcomes, particularly in recipients with concur-rent donor bone marrow cell infusion (DBMI). Methods: Between June 2006 and May 2007, forty living unrelated donor kidney tra...
متن کاملAntibody-mediated rejection following transplantation from an HLA-identical sibling.
Putative antibody-mediated rejection (AMR) in HLA-identical sibling transplantation has rarely been reported and occurred before routine calcineurin inhibitor use. A 29-year-old male developed allograft dysfunction following an HLA-identical renal transplant from his sibling. A pretransplant panel-reactive antibody (PRA) was elevated, pre-transplant crossmatch was negative and no donor-specific...
متن کاملUse of an allograft patch in repair of hypoplastic left heart syndrome may complicate future transplantation.
OBJECTIVE Cryopreserved allograft tissue used in the Norwood procedure for infants with hypoplastic left heart syndrome (HLHS) has the potential to cause marked immunologic sensitization which may complicate potential future heart transplantation, if required. The purpose of this study was to assess the anti-HLA antibody response to allograft patches used in the initial repair of HLHS. METHOD...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of thoracic and cardiovascular surgery
دوره 129 1 شماره
صفحات -
تاریخ انتشار 2005