The Effect of Spatial and Temporal Resolution of Cine Phase Contrast MRI on Wall Shear Stress and Oscillatory Shear Index Assessment
نویسندگان
چکیده
INTRODUCTION Wall shear stress (WSS) and oscillatory shear index (OSI) are associated with atherosclerotic disease. Both parameters are derived from blood velocities, which can be measured with phase-contrast MRI (PC-MRI). Limitations in spatiotemporal resolution of PC-MRI are known to affect these measurements. Our aim was to investigate the effect of spatiotemporal resolution using a carotid artery phantom. METHODS A carotid artery phantom was connected to a flow set-up supplying pulsatile flow. MRI measurement planes were placed at the common carotid artery (CCA) and internal carotid artery (ICA). Two-dimensional PC-MRI measurements were performed with thirty different spatiotemporal resolution settings. The MRI flow measurement was validated with ultrasound probe measurements. Mean flow, peak flow, flow waveform, WSS and OSI were compared for these spatiotemporal resolutions using regression analysis. The slopes of the regression lines were reported in %/mm and %/100ms. The distribution of low and high WSS and OSI was compared between different spatiotemporal resolutions. RESULTS The mean PC-MRI CCA flow (2.5±0.2mL/s) agreed with the ultrasound probe measurements (2.7±0.02mL/s). Mean flow (mL/s) depended only on spatial resolution (CCA:-13%/mm, ICA:-49%/mm). Peak flow (mL/s) depended on both spatial (CCA:-13%/mm, ICA:-17%/mm) and temporal resolution (CCA:-19%/100ms, ICA:-24%/100ms). Mean WSS (Pa) was in inverse relationship only with spatial resolution (CCA:-19%/mm, ICA:-33%/mm). OSI was dependent on spatial resolution for CCA (-26%/mm) and temporal resolution for ICA (-16%/100ms). The regions of low and high WSS and OSI matched for most of the spatiotemporal resolutions (CCA:30/30, ICA:28/30 cases for WSS; CCA:23/30, ICA:29/30 cases for OSI). CONCLUSION We show that both mean flow and mean WSS are independent of temporal resolution. Peak flow and OSI are dependent on both spatial and temporal resolution. However, the magnitude of mean and peak flow, WSS and OSI, and the spatial distribution of OSI and WSS did not exhibit a strong dependency on spatiotemporal resolution.
منابع مشابه
Advanced Quantitative Flow and Wall Shear Stress Analysis at 3T: 2D Vs 3D Time-Resolved MR Velocity Mapping
Introduction: Time-resolved (CINE) phase contrast (PC) MRI permits the assessment of blood flow within entire 3D vascular structures [1, 2]. The resulting high-dimensional datasets (3 spatial dimensions, 3 velocity directions, and time) require new visualization and quantification methods to derive reliable clinical parameters. In this context, an advanced flow quantification tool was developed...
متن کاملMRI-based biomechanical parameters for carotid artery plaque vulnerability assessment.
Carotid atherosclerotic plaques are a major cause of ischaemic stroke. The biomechanical environment to which the arterial wall and plaque is subjected to plays an important role in the initiation, progression and rupture of carotid plaques. MRI is frequently used to characterize the morphology of a carotid plaque, but new developments in MRI enable more functional assessment of carotid plaques...
متن کاملFeasibility of in vivo measurement of carotid wall shear rate using spiral Fourier velocity encoded MRI.
Arterial wall shear stress is widely believed to influence the formation and growth of atherosclerotic plaque; however, there is currently no gold standard for its in vivo measurement. The use of phase contrast MRI has proved to be challenging due to partial-volume effects and inadequate signal-to-noise ratio at the high spatial resolutions that are required. This work evaluates the use of spir...
متن کاملThe effect of turbulence model on predicting the development and progression of coronary artery atherosclerosis
A severe case of stenosis in coronary arteries results in turbulence in the blood flow which may lead to the formation or progression of atherosclerosis. This study investigated the turbulent blood flow in a coronary artery with rigid walls, as well as 80% single and double stenoses on blood flow. A finite element-based software package, ADINA 8.8, was employed to model the blood flow. The hemo...
متن کاملWall Shear Stress of Swine Model with Induced Carotid Artery Stenosis
S. AHN, A. ISHII, D. SHIN, F. VINUELA, S. SINHA Biomedical Engineering, University of California, Los Angeles, CA, United States, Radiological Sciences, University of California, Los Angeles, CA, United States OBJECTIVES Low and/or oscillatory shearing stress at a vessel wall is regarded as a risk factor of the evolution of atherosclerotic plaques . In vivo hemodynamic study concurrent with tem...
متن کامل