Bleb needling with subconjunctival ologen insertion using IOL cartridge

نویسندگان

  • Tanuj Dada
  • Dewang Angmo
  • Shibal Bhartiya
  • Karthikeya Ramananda
چکیده

We describe a novel technique to bleb needling by injecting subconjunctival ologen through an intraocular lens (IOL) delivery system to modulate wound healing in a failing filter. Bleb needling with 26G needle was performed, followed by subconjunctival injection of a biodegradable collagen implant using an IOL delivery system with cartridge in two eyes with a failing filter and high intraocular pressure (IOP). Postoperatively, the bleb was diffusely elevated, and the IOP was maintained between 10 and 14 mmHg at 6 weeks, 3 and 6 months follow-up. Therefore, bleb needling augmented with a biodegradable collagen implant inserted through an IOL injector system is a useful option in the management of failing filter posttrabeculectomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trabeculectomy with combined use of subconjunctival collagen implant and low-dose mitomycin C.

PURPOSE To evaluate outcomes of trabeculectomy with use of a subconjunctival biodegradable collagen implant (Ologen) combined with mitomycin C (MMC). METHODS This retrospective study included 33 eyes of 24 patients with primary open-angle glaucoma who underwent fornix-based trabeculectomy with subconjunctival Ologen implant and MMC (0.1 mg/mL×1 min) between October 2008 and April 2010. Data p...

متن کامل

Needling augmented with topical application of mitomycin C for management of bleb failure.

PURPOSE To study the effect of topical application of mitomycin C on enhancing the efficacy of needling in the management of bleb failure. PATIENTS AND METHODS Thirty-six eyes of 32 consecutive patients with an intraocular pressure over 21 mmHg, without bleb or with a thick, flat bleb after the second postoperative month after trabeculectomy, were included in the study. Needling with mitomyci...

متن کامل

Intraoperative Optical Coherence Tomography Guided Bleb Needling

Two patients with history of trabeculectomy presented with uncontrolled intraocular pressure (IOP) postoperatively. The first patient had a flat and vasularized bleb 10 weeks after the surgery, and the second subject developed encapsulated bleb 3 months postoperatively. Both patients were taken to the operating room and intraoperative optical coherence tomography (OCT) guided bleb needling was ...

متن کامل

[Needle revision of late failing filtering blebs after glaucoma surgery].

PURPOSE To evaluate the results of bleb needling in eyes subjected to filtering surgery six months or more previously. METHODS A retrospective study of 23 eyes in 21 patients subjected to bleb needling performed by means of a 25G needle, 6 months to 23 years after failed filtering surgery (mean 67.3 months). The mean number of bleb needlings was 1.2 and the mean number of 5-fluorouracil subco...

متن کامل

Imaging of blebs after phacotrabeculectomy with Ologen collagen matrix implants.

OBJECTIVE To analyse blebs of phacotrabeculectomies performed with Ologen collagen implants (ProTop & MediKing, Taipei, Taiwan) and to compare these with blebs of mitomycin C (MMC)–augmented phacotrabeculectomies. METHODS 33 participants underwent phacotrabeculectomy with Ologen implants, and 33 controls underwent phacotrabeculectomy with MMC. Blebs were analysed for height and area using ant...