Stability Indicating Assay Method Development and Validation to Simultaneously Estimate Metformin Hydrochloride and Canagliflozin by RP-HPLC

نویسندگان

  • Sonia D’souza
  • S. G. Vasantharaju
چکیده

The focus of this study is to develop and validate a HPLC method to simultaneously estimatemetformin hydrochloride and canagliflozin in bulk using GraceSmart RP-18 column (250× 4.6mm, 5μ)at 30°C.Combination of acetonitrile(ACN) and ammonium acetate bufferin the ratio of 45:55v/v with pH 4.5 was used as mobile phase with 1ml/min flow rate. It was detected by photo diode array detector at 252 nm. The retention timeobserved for metformin hydrochloride and canagliflozin were found to be 4.00 and 5.76 min respectively. The method was developed and found to be linear with correlation coefficients r of 0.9993 and 0.9992 for metformin hydrochloride and canagliflozin respectively within a concentration range of 180μg/ml. Stability studies were performed by exposing the drugs to acidic, basic, oxidative, thermal and photolytic stress conditions with sampleswithdrawn at different time intervals. Analysis of the above samples were done by the developed method. The method to estimate metformin hydrochloride and canagliflozin in bulk drug is easy, accurate, precise and less time consuming.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Validated RP-HPLC-DAD Method for the Simultaneous Estimation of Metformin Hydrochloride and Canagliflozin in Bulk and Pharmaceutical Tablet Dosage form with Forced Degradation Studies

A novel approach was used to develop and validate a rapid isocratic Reversed Phase-High Performance Liquid Chromatographic method for the simultaneous estimation of Metformin Hydrochloride and Canagliflozin in bulk and pharmaceutical tablet dosage form with forced degradation studies. The separation was performed by using Kromasil C18 column (250mm×4.6 mm, 5mm particle size), Waters Alliance e2...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...

متن کامل

Rapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method

An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016