Evaluation of thermal disinfection procedures for hydrophilic contact lenses.

نویسندگان

  • S C Busschaert
  • R C Good
  • J Szabocsik
چکیده

The kinetics and efficacy of moist heat disinfection for hydrophilic contact lenses were investigated by using representative microorganisms of ophthalmic concern and several heat-resistant species. In replicate challenges, 80 degrees C for 10 min and 75 degrees C for 5 min were proven efficacious for moist-heat disinfection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Observation of soft contact lens disinfection with fluorescent metabolic stains.

A rapid fluorescent staining method using a tetrazolium dye and propidium iodide for the in-use assessment of disinfection of Pseudomonas aeruginosa biofilms on soft contact lenses showed that 11 to 13% of cells on lenses remained actively respiring and recoverable by culture methods after 30 min of exposure to 3% hydrogen peroxide.

متن کامل

Susceptibility of Acanthamoeba to soft contact lens disinfection systems.

Members of the genus Acanthamoeba are increasingly recognized as agents of indolent, chronic, infectious keratitis. Recently, Acanthamoeba corneal infection has been reported in some persons who wear soft contact lenses. In this study, three "heat" and three "cold" soft contact lens disinfection systems were tested according to the manufacturers' instructions against Acanthamoeba castellanii an...

متن کامل

Effect of Low Energy Surface Vibration on the Anti-adhesive Properties of Multipurpose Solutions

Contact lenses are a successful form of vision correction. But their use has been associated with an increased risk of microbial keratitis (MK), contact lens related acute red eye (CLARE) as well as contact lens peripheral ulcer (CLPU) (Eltis, 2011). One of the main problems associated with contact lenses is microbial contamination of the lens surface. Microbial contamination further leads to t...

متن کامل

Antimicrobial Efficacy of Multipurpose Disinfecting Solutions in the Presence of Contact Lenses and Lens Cases

OBJECTIVE The aim of this study was to use antimicrobial efficacy endpoint methodology to determine compatibility of multipurpose disinfecting solutions (MPSs), lens cases, and hydrogel lenses for disinfection (AEEMC) against International Organization for Standardization (ISO)-specified microorganisms and clinical ocular isolates of Stenotrophomonas maltophilia. METHODS Six MPSs (PQ/Aldox 1,...

متن کامل

Evaluation of the PuriLens contact lens care system: an automatic care system incorporating UV disinfection and hydrodynamic shear cleaning.

PURPOSE This study evaluates lens care using the PuriLens System, an advanced way to clean and disinfect soft hydrophilic lenses using subsonic agitation and UV radiation, respectively. METHODS A two-period crossover lens cleaning and safety investigation was conducted using 80 patients. Disinfecting efficacy was tested in accordance with standard FDA protocols. Lens compatibility was studied...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 35 3  شماره 

صفحات  -

تاریخ انتشار 1978