Performance of Xpert MTB/RIF RUO assay and IS6110 real-time PCR for Mycobacterium tuberculosis detection in clinical samples.

نویسندگان

  • Melissa B Miller
  • Elena B Popowitch
  • Michael G Backlund
  • Edward P C Ager
چکیده

The Cepheid Xpert MTB/RIF research-use-only (RUO) assay and a laboratory-developed test (LDT) targeting IS6110 were evaluated and compared to mycobacterial culture as the gold standard. The performance characteristics of both molecular assays were determined by using 112 specimens from 90 patients, including 89 pulmonary specimens and 23 extrapulmonary specimens. Of the specimens tested, 37 (33%) were culture positive for the Mycobacterium tuberculosis complex; 29 were pulmonary, and 8 were extrapulmonary. Of these culture-positive specimens, 83% of the pulmonary specimens and 50% of the extrapulmonary specimens were smear positive. There was complete concordance between the smear-positive culture-positive specimens, independent of the anatomical site (100% sensitivity). The sensitivity of the MTB/RIF RUO assay for smear-negative specimens was 60% for pulmonary and 75% for extrapulmonary specimens, while the IS6110 LDT sensitivities were 40% and 0%, respectively. There was also complete concordance among the culture-negative specimens tested. Both assays showed 95% specificity, with four culture-negative specimens testing as positive. A review of patient records indicated that there was a high likelihood of the presence of M. tuberculosis complex DNA in the false-positive specimens. Biosafety analysis was performed and showed an acceptable reduction in organism viability using the processing methods described above. Both molecular assays are suitable for the detection of M. tuberculosis isolates in smear-positive pulmonary and extrapulmonary specimens, while the sensitivity of the detection of M. tuberculosis isolates in smear-negative specimens was variable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Study of a Real-Time PCR Assay Targeting senX3-regX3 versus Other Molecular Strategies Commonly Used in the Diagnosis of Tuberculosis

BACKGROUND Nucleic acid amplification tests are increasingly used for the rapid diagnosis of tuberculosis. We undertook a comparative study of the efficiency and diagnostic yield of a real-time PCR senX3-regX3 based assay versus the classical IS6110 target and the new commercial methods. METHODS This single-blind prospective comparative study included 145 consecutive samples: 76 from patients...

متن کامل

Integrating the Xpert MTB/RIF assay into a diagnostic workflow for rapid detection of Mycobacterium tuberculosis in a low-prevalence area.

The Xpert MTB/RIF assay is a rapid and fully automated real-time PCR assay. The performance of the Xpert MTB/RIF assay as a primary screening test for urgent clinical specimens was evaluated during a 2-year period. The results showed that replacing smear microscopy with the Xpert MTB/RIF assay facilitates laboratory handling and improves the sensitivity and specificity of Mycobacterium tubercul...

متن کامل

Rapid and Accurate Detection of Mycobacterium tuberculosis in Sputum Samples by Cepheid Xpert MTB/RIF Assay—A Clinical Validation Study

BACKGROUND A crucial impediment to global tuberculosis control is the lack of an accurate, rapid diagnostic test for detection of patients with active TB. A new, rapid diagnostic method, (Cepheid) Xpert MTB/RIF Assay, is an automated sample preparation and real-time PCR instrument, which was shown to have good potential as an alternative to current reference standard sputum microscopy and cultu...

متن کامل

Performance of real-time PCR Xpert ®MTB/RIF in diagnosing extrapulmonary tuberculosis.

The real time PCR Xpert ® MTB/RIF is fundamental for rapid diagnosis in paucibacillary respiratory samples and for the detection of multidrug-resistant TB cases. This paper aimed to determine its performance on different extrapulmonary samples. We determined sensitivity, specificity, positive and negative predictive value on respiratory and non-respiratory samples collected from January 2010 to...

متن کامل

Evaluation of a new automated Abbott RealTime MTB RIF/INH assay for qualitative detection of rifampicin/isoniazid resistance in pulmonary and extra-pulmonary clinical samples of Mycobacterium tuberculosis

A new automated real-time PCR assay for the detection of rifampicin (RIF) and isoniazid (INH) resistance in Mycobacterium tuberculosis (MTB) was evaluated. A total of 163 clinical samples (128 pulmonary and 35 extra-pulmonary) were processed using four PCR assay kits: Abbott RealTime MTB RIF/INH, Genotype MTBDRplus, Xpert/MTB RIF, and Anyplex MTB/MDR. The results of phenotypic drug-susceptibili...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 49 10  شماره 

صفحات  -

تاریخ انتشار 2011