Comparison between conventional interrupted high-resolution CT and volume multidetector CT acquisition in the assessment of bronchiectasis.

نویسندگان

  • L E Hill
  • G Ritchie
  • A J Wightman
  • A T Hill
  • J T Murchison
چکیده

The aim of this study was to determine whether there is superior diagnostic accuracy for the detection and exclusion of bronchiectasis using 16-slice CT of the chest (1 mm) compared with conventional high-resolution CT (HRCT) of the chest (10 mm). A prospective study was carried out in patients who were referred for chest CT by a chest physician for the investigation of bronchiectasis over a 1-year period. All scans were performed using a 16-slice CT scanner. In addition to contiguous 1 mm slices, conventional HRCT images (1 mm slice every 10 mm) were prepared. Both datasets were dual read. There were 53 patients with a median age of 62 years (range, 51.5-71.5 years), comprising 14 males and 39 females. 10 of 53 scans had no bronchiectasis in either dataset. 36 patients had bronchiectasis diagnosed on both HRCT and 1 mm scans. Two patients had tubular bronchiectasis on the HRCT scans, which was not confirmed on the 1 mm scans. Five patients had confirmed tubular bronchiectasis on the 1 mm scans, which was not identified on HRCT scans. 40 extra lobes demonstrated bronchiectasis on the 1 mm vs the HRCT scans; of these, half were labelled as definite bronchiectasis on the 1 mm scan. There was a 32% increased confidence with the 1 mm scans compared with conventional HRCT of the chest in the diagnosis of bronchiectasis (p < 0.001). In conclusion, there is improved diagnostic accuracy and confidence for diagnosis and exclusion of bronchiectasis using 16-slice chest CT (1 mm cuts) compared with conventional HRCT of the chest.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism

Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...

متن کامل

An assessment of the Doses Received by Children from CT Examinations Along with the QC Parameters from a Conventional CT System

Introduction: In 2000, the UNSCEAR reported that CT constitutes 5% of all the medical x-ray  examinations and it contributes 34% of the resultant collective dose worldwide. Children are more  sensitive to the ionizing radiations than adults. So, routine quality control tests are expected to be  carried out periodically on the CT scanners. The aim of this research was to estimate the effective  ...

متن کامل

Evaluation of Volumetric Doses of Organs at Risk in Carcinoma Cervix Patients with HDR Intracavitary Brachytherapy and Comparison of CT-based and Conventional Plans

Background: Brachytherapy treatment planning in cervix carcinoma patients using two dimensional (2D) orthogonal images provides only point dose estimates while CT-based planning provides volumetric dose assessment helping in understanding the correlation between morbidity and the dose to organs at risk (OARs) and treatment volume. Objective: Aim of present study is to compare Internationa...

متن کامل

High-resolution CT quantification of bronchiectasis: clinical and functional correlation.

PURPOSE To evaluate clinical relevance of high-resolution computed tomographic (CT) findings in patients with bronchiectasis by using a quantitative high-resolution CT protocol to assess extent of bronchiectasis, severity of bronchial wall thickening, and presence of small-airway abnormalities and mosaic pattern. MATERIALS AND METHODS Sixty Chinese patients with steady-state bronchiectasis un...

متن کامل

Assessment of Contrast Media Volume Injected and Image Contrast in Abdominal Pelvic CT Scan and Related Factors in Referral Hospitals in Mazandaran, Iran

 Background and purpose: Computed tomography scan (CT) is highly capable of diagnosing abdominal and pelvic lesions. Injection of contrast media at appropriate concentration and volume provides the least side effects and the highest image quality. This study aimed at investigating the volume of contrast medium injected and the level of image contrast compared to the standard model, in the imagi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 83 985  شماره 

صفحات  -

تاریخ انتشار 2010