Delayed Dialyzer Reprocessing for Home Hemodialysis.

نویسندگان

  • Andreas Pierratos
  • Robert Francoeur
  • Michaelene Ouwendyk
چکیده

Although dialyzer reuse for home hemodialysis (done by patients at home) has been in practice since the 1960s, it is now almost completely abandoned. The need for dialyzer reuse resurfaced with the renewed interest in daily/nightly forms of home hemodialysis and the associated increase in operating costs. We describe a method of dialyzer reuse based on reprocessing of dialyzers at the center, after they had been stored in a refrigerator at home for 1 week by the patient. Transportation of the dialyzers by either the patient or a transportation service was acceptable to the patients. Despite the lower number of reuses, possibly related to the delayed processing, dialyzer reuse in this setting provided significant financial benefits. Experience with this process for 3 years has not disclosed any negative effects after the initial logistical issues related to dialyzer transportation were resolved. In summary, weekly dialyzer reprocessing at the center provides a solution to the need for dialyzer reuse for the home hemodialysis patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Hemodialysis Adequacy in a Changing World.

Defining adequacy of dialysis remains an elusive goal. The application of the Kt/Vurea concept to clinical dialysis was a major improvement in trying to define a dialysis dose. Intuitively, the Kt/V concept makes a great deal of sense: the urea clearance of the dialyzer during dialysis (K), multiplied by the time (t) of dialysis, divided by the patient's urea distribution volume (V) ought to gi...

متن کامل

Quality assurance for hemodialyzer reprocessing: minimizing risks.

Reprocessing of hemodialyzers is a well-established practice in the United States. In 1999, 80% of the dialysis centers had dialyzer reprocessing programs. Many researchers, including this author, have studied various aspects of performance and quality control for reprocessed hemodialyzers. Much of the literature associated with these studies confirms dialyzer reprocessing can be a safe and eff...

متن کامل

Effects of Hemodialyzer Reuse on Clearances of Urea and b2-Microglobulin

Although dialyzer reuse in chronic hemodialysis patients is commonly practiced in the United States, performance of reused dialyzers has not been extensively and critically evaluated. The present study analyzes data extracted from a multicenter clinical trial (the HEMO Study) and examines the effect of reuse on urea and b2-microglobulin (b2M) clearance by low-flux and high-flux dialyzers reproc...

متن کامل

Dialyzer reuse with peracetic acid does not impact patient mortality.

BACKGROUND AND OBJECTIVES Numerous studies have shown the overall benefits of dialysis filter reuse, including superior biocompatibility and decreased nonbiodegradable medical waste generation, without increased risk of mortality. A recent study reported that dialyzer reprocessing was associated with decreased patient survival; however, it did not control for sources of potential confounding. W...

متن کامل

Anticoagulation in Patients With Acute Renal Failure Treated With Continuous Renal Replacement Therapies.

Although continuous renal replacement therapy (CRRT) provides greater cardiovascular and cerebrovascular stability compared to standard intermittent hemodialysis and/ or hemofiltration, to provide adequate solute removal, the CRRT circuit must function continuously. Patients with acute renal failure are usually prothrombotic, with activation of the contact coagulation cascade and reduction in t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hemodialysis international. International Symposium on Home Hemodialysis

دوره 4 1  شماره 

صفحات  -

تاریخ انتشار 2000