Reliability of simulated robustness testing in fast liquid chromatography, using state-of-the-art column technology, instrumentation and modelling software.

نویسندگان

  • Róbert Kormány
  • Jenő Fekete
  • Davy Guillarme
  • Szabolcs Fekete
چکیده

The goal of this study was to evaluate the accuracy of simulated robustness testing using commercial modelling software (DryLab) and state-of-the-art stationary phases. For this purpose, a mixture of amlodipine and its seven related impurities was analyzed on short narrow bore columns (50×2.1mm, packed with sub-2μm particles) providing short analysis times. The performance of commercial modelling software for robustness testing was systematically compared to experimental measurements and DoE based predictions. We have demonstrated that the reliability of predictions was good, since the predicted retention times and resolutions were in good agreement with the experimental ones at the edges of the design space. In average, the retention time relative errors were <1.0%, while the predicted critical resolution errors were comprised between 6.9 and 17.2%. Because the simulated robustness testing requires significantly less experimental work than the DoE based predictions, we think that robustness could now be investigated in the early stage of method development. Moreover, the column interchangeability, which is also an important part of robustness testing, was investigated considering five different C8 and C18 columns packed with sub-2μm particles. Again, thanks to modelling software, we proved that the separation was feasible on all columns within the same analysis time (less than 4min), by proper adjustments of variables.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Steady-State and Dynamic Simulations of Gas Absorption Column Using MATLAB and SIMULINK

Separation is one of the most important process in all the chemical industries and the gas absorption is the simplest example of separation process which is generally used for the absorption of dilute components from a gaseous mixture. In the present work, a dynamic system of mathematical equation (algebraic and differential) is modeled to predict the behavior of the absorption column using mat...

متن کامل

Simultaneous Determination of Four Preservatives in Foodstuffs by High Performance Liquid Chromatography

Background and objectives:&nbsp; High concentration of preservatives in food may result in gastrointestinal disturbances whereby some patients suffering from asthma, rhinitis, or urticaria. The aim of this study is the introduction and optimization a new method for simultaneous determination of four preservatives (SB, PS, MP, PP) in foodstuff by high performance liquid chromatography. Materi...

متن کامل

Modeling and Simulation of Kuhni Extraction Column Using a Rate-based Model

In this study, liquid-liquid extraction process in a Kuhni extraction column was modeled and simulated. A non-equilibrium dynamic model was developed for modeling liquid-liquid extraction processes based on a rate-based model. The model equations are inclusive of partial and ordinary differential equations which were discretized in column height direction. The population balance model was used ...

متن کامل

A Mushy State Simulated Annealing

It is a long time that the Simulated Annealing (SA) procedure is introduced as a model-free optimization for solving NP-hard problems. Improvements from the standard SA in the recent decade mostly concentrate on combining its original algorithm with some heuristic methods. These modifications are rarely happened to the initial condition selection methods from which the annealing schedules start...

متن کامل

A New Comprehensive Sensor Network Design Methodology for Complex Nonlinear Process Plants

This paper presents an optimal integrated instrumentation sensor network design methodology for complex nonlinear chemical process plants using a Combinatorial Particle Swarm Optimiazation (CPSO) engine. No comprehensive sensor network design approach has been addressed yet in the literature to simultaneously incorporate cost, precision and reliability requirements for nonlinear plant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pharmaceutical and biomedical analysis

دوره 89  شماره 

صفحات  -

تاریخ انتشار 2014