Validity, intra- and inter-observer reliability of automated devices for the assessment of ankle brachial index using photo-plethysmography
نویسندگان
چکیده
BACKGROUND Ankle-brachial-Index (ABI) measured by manual Dopplersonography is an easily assessable marker of global cardiovascular risk. The aim of this study was to establish novel photo-plethysmography (PPG)-based ABI assessments in an epidemiologic context and to compare its results with those of Doppler. METHODS Two devices for PPG-based ABI assessments (Vicorder, Vascular Explorer) were tested and compared against Doppler in 56 putatively healthy subjects. We determined acceptance, time requirements, agreement of repeat measurements, agreement with Doppler and intra- and inter-observer concordances for both devices and compared the results. Differences between cuff inflation- and deflation-based methods were also studied for Vascular Explorer. RESULTS Acceptance was similar for both devices but Vascular Explorer was more time consuming. Agreement of multiple measurements was moderate for both methods highlighting the importance of measurement replicates. Both automated devices showed significantly higher ABI compared to Doppler which can be traced back to higher brachial pressures (Vicorder) or higher ankle pressures (Vascular Explorer). This effect is more pronounced for Vascular Explorer but can be ameliorated using the deflation method of measurement. Intra-observer concordances were similar. Inter-observer concordance was non-significantly better for Vicorder. CONCLUSIONS Both devices proved to be feasible in epidemiologic studies, but compared to Doppler, do not constitute an advantage regarding time requirement and accuracy of ABI assessment. Since PPG-based ABI values are inflated compared to Doppler, it will be necessary to adjust Doppler-based cut-offs for risk stratification.
منابع مشابه
Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment
Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...
متن کاملThe reliability of toe systolic pressure and the toe brachial index in patients with diabetes
BACKGROUND The Ankle Brachial Index is a useful clinical test for establishing blood supply to the foot. However, there are limitations to this method when conducted on people with diabetes. As an alternative to the Ankle Brachial Index, measuring Toe Systolic Pressures and the Toe Brachial Index have been recommended to assess the arterial blood supply to the foot. This study aimed to determin...
متن کاملThe clinimetric qualities of patient-assessed instruments for measuring chronic ankle instability: A systematic review
BACKGROUND The assessment of outcomes from the patient's perspective becomes more recognized in health care. Also in patients with chronic ankle instability, the degree of present impairments, disabilities and participation problems should be documented from the perspective of the patient. The decision about which patient-assessed instrument is most appropriate for clinical practice should be b...
متن کاملNon-invasive assessment of peripheral arterial disease: Automated ankle brachial index measurement and pulse volume analysis compared to duplex scan
OBJECTIVES This cross-sectional study aimed to individually and cumulatively compare sensitivity and specificity of the (1) ankle brachial index and (2) pulse volume waveform analysis recorded by the same automated device, with the presence or absence of peripheral arterial disease being verified by ultrasound duplex scan. METHODS Patients (n=205) referred for lower limb arterial assessment u...
متن کاملRepeatability of Oscillometric Determinations of the Ankle-Brachial Index. The Atherosclerosis Risk in Communities (ARIC) Study
Background: The ankle-brachial index (ABI) is a noninvasive and inexpensive means to assess lower extremity artery patency with established validity. Low ABI values are predictive of cardiovascular morbidity and all-cause mortality. Automated, oscillometric devices are commonly used to measure ABI in population studies for timeefficiency and to reduce observer-dependent variability. The repeata...
متن کامل