Zinc phosphate as a definitive cement for implant-supported crowns and fixed dentures
نویسنده
چکیده
Implant-supported dental prostheses can be retained by a screw or cement. Implant-supported fixed partial dentures have a passive fit. A passive fit means there is an internal gap between the abutment surface and the intaglio of the retainer to insure that there is no lateral pressure on the supporting implants or friction upon seating of the prosthesis. This gap is filled with cement for retention of the prosthesis. Any lateral pressure may cause marginal bone loss or periimplantitis. Also, there is usually a microscopic gap at the margin of a crown retainer that exposes the cement to oral fluids. The solubility of zinc phosphate (ZOP) cement is a definite liability due to the risk for cement dissolution. In fixed prostheses, the dissolution of the cement of one or more retainers would cause a transfer of the occlusal load to the retained unit(s). The resulting rotation and lifting of the cement-retained implants from occlusal and parafunctional loads could cause loss of osseointegration of the abutment-retained implant(s). ZOP cement may not be indicated for implant-supported fixed partial dentures or splints. Cement dissolution in single unit probably only involves re-cementation, if the patient does not swallow or aspirate the crown.
منابع مشابه
Comparison of uniaxial resistance forces of cements used with implant-supported crowns.
PURPOSE Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations. While the functional life spans of these cements are unpredictable, the relative retentiveness of various permanent and provisional cements between dental alloys and titanium abutments is not well documented. The aim of this study was to compare the uniaxial resistance force...
متن کاملThe effect of luting agents on the retention of dental implant-supported crowns.
BACKGROUND This study was designed to evaluate the retentive strength of 7 different luting agents on cement-retained implant abutment/analog assemblies. METHODS Fifty-six Steri-Oss implant abutment/analog assemblies and cast superstructures were randomly divided into 7 groups: definitive cements included zinc phosphate cement, Advance, All-Bond 2, Panavia F, and Durelon, while provisional ce...
متن کاملMarginal Fit Metal-Ceramic and In-Ceram Single Crown Cement retained in Implant-supported Abutments.
INTRODUCTION This study evaluated the cervical fit of cemented metal-ceramic and In-Ceram implant-supported crowns, before and after the cementing procedure. MATERIALS AND METHODS Twenty crowns cemented on implant abutments are divided into two groups (n = 10): Group 1 -cemented metal-ceramic crowns and group 2 - cemented In-Ceram crowns. The marginal adaptations before and after cementation ...
متن کاملAn in vitro assessment of circumferential grooves on the retention of cement-retained implant-supported crowns.
STATEMENT OF PROBLEM Crowns cemented on short implant abutments may have insufficient retention. PURPOSE The purpose of this study was to evaluate the effect of circumferential grooves on the retention of cemented cast copings on implant abutments. MATERIAL AND METHODS Sixty similarly-shaped implant abutments were divided into 4 groups (n=15): without grooves, with 1 groove, with 2 grooves,...
متن کاملContemporary Dental Cements to Meet the Challenges of Today’s Restorative Dentistry
The search for an all-purpose luting system for final cementation that fulfills the properties necessary for definitive placement of cast metal, porcelain-metal, resin, and all-ceramic fullcoverage restorations has been limited by the physical properties of the cements that have been available. Currently the clinician has many choices for cementation. Despite the challenges of the current resto...