Flow-Dependent Uptake of ¹²³I-CMICE-013, a Novel SPECT Perfusion Agent, Compared with Standard Tracers.

نویسندگان

  • R Glenn Wells
  • Lihui Wei
  • Julia Petryk
  • Yin Duan
  • Brian Marvin
  • Rachel Timmins
  • Karen Soueidan
  • Pasan Fernando
  • Corinne Bensimon
  • Terrence D Ruddy
چکیده

UNLABELLED Rotenone derivatives have shown promise in myocardial perfusion imaging (MPI). CMICE-013 is a novel (123)I-labeled rotenone derivative developed for SPECT MPI. The objective of this study was to assess the image quality of CMICE-013 and compare its uptake with tetrofosmin, sestamibi, and (201)Tl in vivo in a porcine model of stress-induced myocardial ischemia. METHODS Microspheres were injected simultaneously with the radiotracer injections at rest and stress to measure blood flow. Mimicking a 1-d tetrofosmin protocol, stress imaging used 3 times as much activity and occurred 1 h after the rest injection. SPECT images were obtained at both rest and stress. After imaging, the heart was sectioned into 44-50 pieces. In each heart sample, the tracer uptake was measured in a γ counter. The images were aligned, and the decay-corrected ratio of the signals at rest and stress was used to separate the well-counter signal into rest and stress components. The uptake at rest and stress was compared with microsphere flow measurements. RESULTS The CMICE-013 images showed good contrast between the heart and surrounding organs, with heart-to-liver and heart-to-lung uptake ratios similar to those of the standard tracers. Uptake of CMICE-013 was 1.5% of the injected dose at rest and increased more rapidly with increased blood flow than did the standard SPECT tracers. The percentage injected dose of CMICE-013 taken up by the heart was greater (P < 0.05) than (201)Tl, tetrofosmin, or sestamibi at flows greater than 1.5 mL/min/g. CONCLUSION CMICE-013 is a promising new SPECT MPI agent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biodistribution and radiodosimetry of a novel myocardial perfusion tracer 123I-CMICE-013 in healthy rats

BACKGROUND 123I-CMICE-013 is a novel radiotracer previously reported to have promising characteristics for single-photon emission computed tomography (SPECT) myocardial perfusion imaging. We evaluated the biokinetics and radiodosimetry of this rotenone-like 123I-labeled tracer in a microSPECT imaging-based study. METHODS 37 to 111 MBq of 123I-CMICE-013 was synthesized and administered intrave...

متن کامل

Abnormal cerebral blood flow in methamphetamine abusers assessed by brain perfusion single emission computed tomography

Introduction:Amphetamines are central nervous system (CNS) stimulant substances and amphetamine abuse is considered a growing problem in our country. Previous studies revealed destructive effects of amphetamines on metabolism, perfusion and structure of brain. The aim of current study was evaluating regional cerebral blood flow (rCBF) disturbances in methamphetamine (MA) abuser...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Diffuse bilateral breast uptake on the myocardial perfusion SPECT of a nursing female

  Bilateral diffuse intense breast uptake was noted in a 40 year old female who was evaluated with Tc-99m sestamibi (MIBI) myocardial perfusion scan for possible ischemia. She was breast feeding her 1.5 year old child. The intense uptake in the breasts was superimposed on the apical and anteroapical regions of the myocardium and caused interpretation problem. We recom...

متن کامل

Covid-19 manifestation on Tl-201 myocardial perfusion SPECT/CT

A 67 years old woman was referred to nuclear medicine center for myocardial perfusion imaging (MPI) for assessment of ischemic heart dieses (IHD).She had a history of atypical chest pain and dyspnea since about 10 days before admission. The MPI SPECT/CT was performed by stress/redistribution Tl-201 protocol. MPI was interpreted as relatively good coronary flow with no appreciable stress induced...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 56 5  شماره 

صفحات  -

تاریخ انتشار 2015