Motion robust PPG-imaging through color channel mapping.
نویسندگان
چکیده
Photoplethysmography (PPG)-imaging is an emerging noninvasive technique that maps spatial blood-volume variations in living tissue with a video camera. In this paper, we clarify how cardiac-related (i.e., ballistocardiographic; BCG) artifacts occur in this imaging modality and address these using algorithms from the remote-PPG literature. Performance is assessed under stationary conditions at the immobilized hand. Our proposal outperforms the state-of-the-art, blood pulsation imaging [Biomed. Opt. Express5, 3123 (2014). ], even in our best attempt to create diffused illumination. BCG-artifacts are suppressed to an order of magnitude below PPG-signal strength, which is sufficient to prevent interpretation errors.
منابع مشابه
A Robust Dynamic Heart-Rate Detection Algorithm Framework During Intense Physical Activities Using Photoplethysmographic Signals
Dynamic accurate heart-rate (HR) estimation using a photoplethysmogram (PPG) during intense physical activities is always challenging due to corruption by motion artifacts (MAs). It is difficult to reconstruct a clean signal and extract HR from contaminated PPG. This paper proposes a robust HR-estimation algorithm framework that uses one-channel PPG and tri-axis acceleration data to reconstruct...
متن کاملRemote simultaneous dual wavelength imaging photoplethysmography: a further step towards 3-D mapping of skin blood microcirculation
This paper presents a camera-based imaging photoplethysmographic (PPG) system in the remote detection of PPG signals, which can contribute to construct a 3-D blood pulsation mapping for the assessment of skin blood microcirculation at various vascular depths. Spot measurement and contact sensor have been currently addressed as the primary limitations in the utilization of conventional PPG syste...
متن کاملPortable Wrist Located Heart Rate Moni- Toring Device
Portable heart rate monitoring devices are classically composed of a processing device and an external probe (e.g. electronic stethoscope, optical measure at ear lobe, chest belt for ECG based measurement, etc.). The use of an external probe is often considered as a reduction of the comfort. We propose a new fully integrated measurement system that is located at the wrist. This system is based ...
متن کاملColor high dynamic range imaging: The luminance-chrominance approach
This paper presents a novel and efficient approach to color in high dynamic range (HDR) imaging. In contrast to state-of-theart methods, we propose to move the complete HDR imaging process from RGB to a luminance-chrominance color space. Our aim is to get a computationally efficient technique and to avoid any possible color distortions originating from the three RGB color channels processed sep...
متن کاملImproving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph
Photoplethysmographic (PPG) waveforms are used to acquire pulse rate (PR) measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA), limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical optics express
دوره 7 5 شماره
صفحات -
تاریخ انتشار 2016