T1- Thresholds in Black Holes Increase Clinical-Radiological Correlation in Multiple Sclerosis Patients

نویسندگان

  • Christian Thaler
  • Tobias Faizy
  • Jan Sedlacik
  • Brigitte Holst
  • Jan-Patrick Stellmann
  • Kim Lea Young
  • Christoph Heesen
  • Jens Fiehler
  • Susanne Siemonsen
  • Sreeram V. Ramagopalan
چکیده

BACKGROUND Magnetic Resonance Imaging (MRI) is an established tool in diagnosing and evaluating disease activity in Multiple Sclerosis (MS). While clinical-radiological correlations are limited in general, hypointense T1 lesions (also known as Black Holes (BH)) have shown some promising results. The definition of BHs is very heterogeneous and depends on subjective visual evaluation. OBJECTIVE We aimed to improve clinical-radiological correlations by defining BHs using T1 relaxation time (T1-RT) thresholds to achieve best possible correlation between BH lesion volume and clinical disability. METHOD 40 patients with mainly relapsing-remitting MS underwent MRI including 3-dimensional fluid attenuated inversion recovery (FLAIR), magnetization-prepared rapid gradient echo (MPRAGE) before and after Gadolinium (GD) injection and double inversion-contrast magnetization-prepared rapid gradient echo (MP2RAGE) sequences. BHs (BHvis) were marked by two raters on native T1-weighted (T1w)-MPRAGE, contrast-enhancing lesions (CE lesions) on T1w-MPRAGE after GD and FLAIR lesions (total-FLAIR lesions) were detected separately. BHvis and total-FLAIR lesion maps were registered to MP2RAGE images, and the mean T1-RT were calculated for all lesion ROIs. Mean T1 values of the cortex (CTX) were calculated for each patient. Subsequently, Spearman rank correlations between clinical scores (Expanded Disability Status Scale and Multiple Sclerosis Functional Composite) and lesion volume were determined for different T1-RT thresholds. RESULTS Significant differences in T1-RT were obtained between all different lesion types with highest T1 values in visually marked BHs (BHvis: 1453.3±213.4 ms, total-FLAIR lesions: 1394.33±187.38 ms, CTX: 1305.6±35.8 ms; p<0.05). Significant correlations between BHvis/total-FLAIR lesion volume and clinical disability were obtained for a wide range of T1-RT thresholds. The highest correlation for BHvis and total-FLAIR lesion masks were found at T1-RT>1500 ms (Expanded Disability Status Scale vs. lesion volume: rBHvis = 0.442 and rtotal-FLAIR = 0.497, p<0.05; Multiple Sclerosis Functional Composite vs. lesion volume: rBHvis = -0.53 and rtotal-FLAIR = -0.627, p<0.05). CONCLUSION Clinical-radiological correlations in MS patients are increased by application of T1-RT thresholds. With the short acquisition time of the MP2RAGE sequences, quantitative T1 maps could be easily established in clinical studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Role of T1-Weighted Derived Measures of Neurodegeneration for Assessing Disability Progression in Multiple Sclerosis

INTRODUCTION Multiple sclerosis (MS) is characterised by the accumulation of permanent neurological disability secondary to irreversible tissue loss (neurodegeneration) in the brain and spinal cord. MRI measures derived from T1-weighted image analysis (i.e., black holes and atrophy) are correlated with pathological measures of irreversible tissue loss. Quantifying the degree of neurodegeneratio...

متن کامل

Predictive value of lesions for relapses in relapsing-remitting multiple sclerosis.

BACKGROUND AND PURPOSE Recent studies have suggested that enhancing lesions on contrast-enhanced T1-weighted MR images are predictive of impending exacerbations in cases of relapsing-remitting multiple sclerosis. We examined whether enhancing lesions, new enhancing lesions, and new hypointense lesions ("black holes") could accurately predict exacerbations in a cohort of 50 patients with relapsi...

متن کامل

Disappearing "T1 black holes" in an animal model of multiple sclerosis.

Brain MRI in multiple sclerosis (MS) frequently shows areas of hypointensity in the white matter on T1 weighted sequences ("T1 black holes"). These areas are thought to be consistent with irreversible axonal loss. In this study T1 black holes were characterized in Theiler's Murine Encephalitis Virus infection, an established model of demyelinating diseases in mice. The spectrum of TMEV is broad...

متن کامل

Improving the clinical correlation of multiple sclerosis black hole volume change by paired-scan analysis☆

The change in T 1-hypointense lesion ("black hole") volume is an important marker of pathological progression in multiple sclerosis (MS). Black hole boundaries often have low contrast and are difficult to determine accurately and most (semi-)automated segmentation methods first compute the T 2-hyperintense lesions, which are a superset of the black holes and are typically more distinct, to form...

متن کامل

Development of hypointense lesions on T1-weighted spin-echo magnetic resonance images in multiple sclerosis: relation to inflammatory activity.

OBJECTIVE To evaluate whether degree of inflammatory activity in multiple sclerosis, expressed by frequency of gadolinium enhancement, has prognostic value for development of hypointense lesions on T1-weighted spin-echo magnetic resonance images, a putative marker of tissue destruction. DESIGN Cohort design with long-term follow-up. Thirty-eight patients with multiple sclerosis who in the pas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015