Comparison of Cartesian and Non-Cartesian Real-Time MRI Sequences at 1.5T to Assess Velar Motion and Velopharyngeal Closure during Speech

نویسندگان

  • Andreia C. Freitas
  • Marzena Wylezinska
  • Malcolm J. Birch
  • Steffen E. Petersen
  • Marc E. Miquel
چکیده

Dynamic imaging of the vocal tract using real-time MRI has been an active and growing area of research, having demonstrated great potential to become routinely performed in the clinical evaluation of speech and swallowing disorders. Although many technical advances have been made in regards to acquisition and reconstruction methodologies, there is still no consensus in best practice protocols. This study aims to compare Cartesian and non-Cartesian real-time MRI sequences, regarding image quality and temporal resolution trade-off, for dynamic speech imaging. Five subjects were imaged at 1.5T, while performing normal phonation, in order to assess velar motion and velopharyngeal closure. Data was acquired using both Cartesian and non-Cartesian (spiral and radial) real-time sequences at five different spatial-temporal resolution sets, between 10 fps (1.7×1.7×10 mm3) and 25 fps (1.5×1.5×10 mm3). Only standard scanning resources provided by the MRI scanner manufacturer were used to ensure easy applicability to clinical evaluation and reproducibility. Data sets were evaluated by comparing measurements of the velar structure, dynamic contrast-to-noise ratio and image quality visual scoring. Results showed that for all proposed sequences, FLASH spiral acquisitions provided higher contrast-to-noise ratio, up to a 170.34% increase at 20 fps, than equivalent bSSFP Cartesian acquisitions for the same spatial-temporal resolution. At higher frame rates (22 and 25 fps), spiral protocols were optimal and provided higher CNR and visual scoring than equivalent radial protocols. Comparison of dynamic imaging at 10 and 22 fps for radial and spiral acquisitions revealed no significant difference in CNR performance, thus indicating that temporal resolution can be doubled without compromising spatial resolution (1.9×1.9 mm2) or CNR. In summary, this study suggests that the use of FLASH spiral protocols should be preferred over bSSFP Cartesian for the dynamic imaging of velopharyngeal closure, as it allows for an improvement in CNR and overall image quality without compromising spatial-temporal resolution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerating Real-time MRI of speech using spiral through-time GRAPPA

PURPOSE: Real-time MRI (RT-MRI) is a powerful tool to safely assess and quantify the vocal tract dynamics during speech production. Applications are numerous including addressing open questions in speech science, and informing treatment plans in clinical applications (e.g., oropharyngeal cancer). RT-MRI is intrinsically challenged by trade-offs amongst the spatio-temporal resolution, slice cove...

متن کامل

نتایج درمانی تزریق توام پلاسمای غنی از پلاکت و چربی در بیماران مبتلا به نارسایی ولوفارنژیال

Background: Velopharyngeal insufficiency causes hypernasal vocal quality and can also result in audible nasal air emission and difficulty in producing pressure consonants. The resulting speech is often socially unacceptable and can be difficult to understand. Platelet-rich plasma is an autologous derivative of whole blood. Today, the importance of clinical use of Platelet-rich plasma in the pla...

متن کامل

Patterns and Grade of Velopharyngeal Closure in Candidates for Adenotonsillectomy

Introduction: The most common type of velopharyngeal valve (VPV) closure is a matter of controversy.The aim of this study was to estimate the most common type of VPV closure, including identification of the type and grade of VPV closure among Egyptian children.  Materials and Methods: This study included patients who were candidates for adenotonsillectomy. In these cases, video-nasoendoscopy an...

متن کامل

Quantitative analysis of the velopharyngeal sphincter function during speech.

OBJECTIVE This study reports a new concept for quantitative analysis of velopharyngeal function using electromagnetic articulography and simultaneous transoral video endoscopy. PARTICIPANTS The velopharyngeal closure mechanism was studied in 16 healthy German subjects during production of the vowel-consonant-vowel sequences /afa/ and /apa/. DESIGN Velar movements in the sagittal and vertica...

متن کامل

Comparison of Cartesian and radial acquisition on short-tau inversion recovery (STIR) sequences in breast MRI

OBJECTIVE The purpose of this study was to compare two short-tau inversion recovery (STIR) sequences, Cartesian and radial (BLADE) acquisitions, for breast magnetic resonance imaging (MRI) examinations. MATERIALS AND METHODS Ninety-six women underwent 1.5 T breast MRI exam (48 Cartesian and 48 BLADE). Qualitative analysis including image artifacts, image quality, fat-suppression, chest-wall d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016