Quantitative determination of octadecenedioic acid in human skin and transdermal perfusates by gas chromatography-mass spectrometry.

نویسندگان

  • Anja Judefeind
  • Peet Jansen van Rensburg
  • Stephan Langelaar
  • Johann W Wiechers
  • Jeanetta du Plessis
چکیده

A gas chromatographic (GC) method with mass spectrometric (MS) detection is developed and validated for the accurate and precise determination of octadecenedioic acid (C18:1 DIOIC) in human skin samples and transdermal perfusates. C18:1 DIOIC is extracted using methanol. The saturated analogue 1,18-octadecanedioic acid (C18:0 DIOIC) is added as internal standard. Prior to analysis, both compounds are converted to their trimethylsilylated derivatives using N,O-bis(trimethylsilyl)trifluoroacetamide with 15% trimethylchlorosilane. Quantitation is performed in selected ion monitoring mode with a limit of quantitation of 250 ng/mL. Linearity with a correlation coefficient of 0.998 is obtained over a concentration range of 250-2000 ng/mL. Values for within-day accuracy range from 94.5% to 102.4%, and from 97.5% to 105.8% for between-day accuracy. Within- and between-day precision values are better than 5% and 7%, respectively. The recovery values from the various matrices vary from 92.6% to 104.0%. The GC-MS method is employed for the determination of C18:1 DIOIC after application of an emulsion containing the active ingredient onto human skin in vitro. The results demonstrate that the method is suitable for the determination of C18:1 DIOIC in human skin samples and transdermal perfusates.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Perchloroethylene Analysis by Chemical Oxidation and Determination of Intermediate Products by Gas Chromatography, Mass Spectrometry

Abstract Background and Objective: Perchloroethylene (PCE) is a chlorinated hydrocarbon used as a solvent in many industrial processes. In contaminated water and soil a great deal of PCE is found. This study aimed to determine the rate of decomposition of PCE occurred after advanced oxidation. Material and Methods: In this descriptive-analytic study conducted (2011) in public health faculty...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Relative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation

The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...

متن کامل

Relative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation

The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 46 6  شماره 

صفحات  -

تاریخ انتشار 2008