Novel LTCC-potentiometric microfluidic device for biparametric analysis of organic compounds carrying plastic antibodies as ionophores: application to sulfamethoxazole and trimethoprim.

نویسندگان

  • S A A Almeida
  • E Arasa
  • M Puyol
  • C S Martinez-Cisneros
  • J Alonso-Chamarro
  • M C B S M Montenegro
  • M G F Sales
چکیده

Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol-gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about -58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes -54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of new carbon paste electrodes based on gold nano-particles self-assembled to mercapto compounds as suitable ionophores for potentiometric determination of Copper ions

In the present study, we investigate the potentiometric behavior of Cu2+ carbon paste electrodes based on two mercapto compounds 2-Ethylmino-5-Mercapto-1,3,4-Thiadiazole (EAMT) and 2-Acetylamino-5-mercapto-1,3,4-thiadiazole (AAMT) self-assembled on gold nano-paricle (GNP) as ionophore. Then, the results obtained from the modified electrodes are compared. The self-assembled ionophores exhibit a ...

متن کامل

Recent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review

Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...

متن کامل

Potentiometric Determination of Acidity Constants of Some Synthesized Organic Compounds in Organic-Water Media

The acidity constants of some synthesized protonated pyrazolo quinazoline compounds were determined potentiometrically at ionic strength of 0.1 M in DMF: water (60:40 v/v) system at different temperatures (298.15 K to 318.15 K). The pKa values have been found to increase with increasing electron-donating nature of substitutions. Some thermodynamics parameters such as enthalpy (ΔH°), Gibb’s free...

متن کامل

Determination of Sulfamethoxazole and Trimethoprim in Pharmaceuticals by Visible and UV Spectrophotometry

A method for the simultaneous determination of sulfamethoxazole (SMX) and trimethoprim (TMP), based on a direct determination of SMX after diazotization and coupling with 2-naphthol by visible spectrophotometry and an indirect determination of TMP in the UV region by difference was developed. By the suggested procedure, it was possible to analyze SMX and TMP in pharmaceutical preparations witho...

متن کامل

Determination of Sulfamethoxazole and Trimethoprim in Pharmaceuticals by Visible and UV Spectrophotometry

A method for the simultaneous determination of sulfamethoxazole (SMX) and trimethoprim (TMP), based on a direct determination of SMX after diazotization and coupling with 2-naphthol by visible spectrophotometry and an indirect determination of TMP in the UV region by difference was developed. By the suggested procedure, it was possible to analyze SMX and TMP in pharmaceutical preparations witho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 30 1  شماره 

صفحات  -

تاریخ انتشار 2011