Solvent strength and selectivity on a porous graphitized carbon column separated by a spectral mapping technique using barbiturates as solutes.

نویسندگان

  • E Forgács
  • T Cserháti
چکیده

A spectral mapping technique (SPM) was employed for separating the strength and selectivity of the retention of 41 barbituric acid derivatives and 5 organic modifiers on a porous graphitized carbon column (PGC). The potency values calculated by SPM were considered to be indicators of the capacity of drugs to bind to the surface of PGC and the capacity of organic modifiers to remove the drugs from the surface. The dimensionality of the multidimensional selectivity maps was reduced to two by a nonlinear mapping technique. Calculations indicated that molecular lipophilicity plays a negligible role in the strength and selectivity of retention, proving that the retention mechanism of PGC deviates from those of traditional reversed-phase stationary phases. Sterical and electronic parameters exerted the highest influence on the retention, emphasizing the importance of the polar interaction and the sterical correspondence between the surface of PGC and the solute molecules.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous effect of organic modifier and physicochemical parameters of barbiturates on their retention on a narrow-bore PGC column.

The retention time of 22 barbituric acid derivatives was measured on a narrow-bore porous graphitized carbon (PGC) column using water-dioxane mixtures as mobile phases. The capacity factor (k), theoretical plate number (N), and asymmetry factor (AF) were calculated for each solute in each mobile phase. The relationships between chromatographic characteristics and physicochemical parameters of s...

متن کامل

Catalytically Graphitized Electrospun Carbon Nanofibers Adorned with Nickel Nanoparticles for Catalysis Applications

Catalytically graphitized electrospun carbon nanofibers adorned uniformly with fine nickel nanoparticles were successfully prepared. The procedure was based on the electrospinning technique and the use of nickel precursor to create both graphitized nanofibers and nickel nanoparticles under a relatively low-temperature heat treatment. The X-ray diffraction and Raman results clearly proved cataly...

متن کامل

Solvent Pre-treated Effects of Carbon Nanotube-supported Cobalt Catalysts on Activity and Selectivity of Fischer-Tropsch Synthesis

In this study, the effect of preparation technique of carbon nanotube (CNT)-supported cobalt catalysts on the activity and selectivity of Fischer-Tropsch synthesis (FTS) was studied. Different concentrations of acetic acid were used for the pretreatment of the catalyst support to modify the surface properties of CNT. This modification improved the reduction degree and dispersion of supported co...

متن کامل

Complementing reversed-phase selectivity with porous graphitized carbon to increase the metabolome coverage in an on-line two-dimensional LC-MS setup for metabolomics

Efficient and robust separation methods are indispensable in modern LC-MS based metabolomics, where high-resolution mass spectrometers are challenged by isomeric and isobaric metabolites. The optimization of chromatographic separation hence remains an invaluable tool in the comprehensive analysis of the chemically diverse intracellular metabolome. While it is widely accepted that a single metho...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 2001