Collimator characteristics for radioisotope scanning.
نویسندگان
چکیده
For scintigraphic instruments such as scanners and scintillation cameras, collimatore with greatly dif ferent characteristics have become available during recent years. In general little information is given concerning the performance of focused collimatore to the physician or physicist who has to select the proper collimator for a particular application.! Only the number of holes, the focal length and the spatial resolution of the collimator at the focal plane are provided by most manufacturers. The present paper describes briefly the funda mental parameters of collimator-detector systems and their significance. The characteristics of colli matore for some commercial scanners are given and corresponding data for other makes of scanners as well as for scintillation cameras should become avail able shortly.
منابع مشابه
Radioisotope scanning in auxiliary liver transplantation.
The same general techniques were used in both the canine and human studies. Intravenously administered rose bengal 1131 was administered to dogs in a dose of 50 microcuries and to patients in a dose of 150 microcuries; scans were obtained at 5 minutes. In the canine experiments employing gold, 50 microcuries of Aulg8 were used with scanning at 15 minutes; in 2 adult human beings 200 microcuries...
متن کاملCollimator angulation error and its effect on SPECT.
Angulation errors in collimator septa degrade tomographic resolution in SPECT due to mispositioning of events in the projection data. These errors should be small compared to other contributions to SPECT system resolution, such as intrinsic camera and collimator resolution, gantry alignment, and algorithmic smoothing. We describe a radioisotope technique to measure septal angulation errors over...
متن کاملImproved Detection of Sentinel Lymph Nodes in SPECT/CT Images Acquired Using a Low- to Medium-Energy General-Purpose Collimator.
PURPOSE The use of the low-energy high-resolution (LEHR) collimator for lymphoscintigraphy causes the appearance of star-shaped artifacts at injection sites. The aim of this study was to confirm whether the lower resolution of the low- to medium-energy general-purpose (LMEGP) collimator is compensated by decrease in the degree of septal penetration and the reduction in star-shaped artifacts. ...
متن کاملSPECT using a specially designed cone beam collimator.
A specially designed high resolution converging collimator having a focal length of 50 cm has been evaluated for cone beam single photon emission computed tomography (SPECT). The focal region was investigated by imaging a point source placed at the expected focal point and along the central ray of the collimator in front of and behind the focal point. Technetium-99m point source sensitivities m...
متن کاملEfficacy of high-energy collimator for sentinel node lymphoscintigraphy of early breast cancer patients
INTRODUCTION Lymphoscintigraphy is an important part of sentinel node mapping in breast cancer patients. Sometimes star shaped artefacts due to septal penetration can be problematic during imaging. In the current study, we evaluated the possibility of high energy (HE) collimators use for lymphoscintigraphy. PATIENTS AND METHODS Twenty patients with early breast carcinoma were included. Thirty...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 11 3 شماره
صفحات -
تاریخ انتشار 1970