Polarized Zeeman-effect flameless atomic absorption spectrometry of cadmium, copper, lead, and manganese in human kidney cortex.

نویسندگان

  • P A Pleban
  • J Kerkay
  • K H Pearson
چکیده

We used polarized Zeeman-effect flameless atomic absorption spectroscopy to quantitatively measure cadmium, copper, lead, and manganese in a nitric acid digest of lyophilized human kidney cortex. Within-run coefficients of variation for cadmium, copper, lead, and manganese, 15.3, 177.2, 84.2, and 56.3 microgram/L, respectively, were 4.1, 6.3, 3.7, and 5.6%, respectively. Between-run coefficients of variation were 6.9, 5.5, 5.9, and 6.3%, respectively, for cadmium, copper, lead, and manganese concentrations of 135.1, 12.8, 2.72, and 3.80 microgram/g, respectively. For cadmium, copper, lead, and manganese digest concentrations (mean +/- SE) of 15.3 +/- 0.6, 41.4 +/- 2.6, 9.4 +/- 0.6, and 20.9 +/- 0.4 microgram/L, respectively, the detection limits were 5.2 microgram/L for copper, 1.2 microgram/L for both cadmium and lead, and 0.8 microgram/L for manganese. Assays were linear to 75 microgram/L for cadmium, 100 microgram/L for manganese, and 200 microgram/L for copper and lead. Average analytical recoveries for the four metals ranged between 95 and 101%. Because these metals were quantitated in the same digest of kidney cortex, the values for each digest gave a trace-metal profile for each autopsy specimen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved determination of manganese in hair by use of a mini-autoclave and flameless atomic absorption spectrometry with Zeeman background correction: an evaluation in unexposed subjects.

Motivated by the relatively wide range of values published hitherto, we offer a new, reliable method for determination of manganese in hair from unexposed human subjects. By using a mini-autoclave, we have developed a method that obviates loss of manganese during digestion and, thanks to use of a Teflon receptacle and rigorous methodology, contamination has been minimized. We used Zeeman flamel...

متن کامل

Measurement of cadmium residues in muscle, liver and kidney of cattle slaughtered in Isfahan abattoir using grafite furnace atomic absorption spectrometry (GFAAS): a preliminary study

The aim of the present study was to determine the levels of cadmium in the muscle, liver and kidney of cattle from Isfahan and to compare the results with those reported by other countries and with the maximum acceptable levels for human consumption. Samples of muscle, liver and kidney from 60 animals aged 1–10- year-old were collected from the carcasses slaughtered at Isfahan abattoir. Samples...

متن کامل

Determination of Metal Contents in Edible Vegetable Oils Produced in Iran Using Microwave-assisted Acid Digestion

The concentration of heavy metals in vegetable oils is an important criterion for the assessment of oil qualities with regard to freshness, keeping properties, storage and their influence on human nutrition and health. Trace heavy metals in vegetable oils are known to have an effect on the rate of oil oxidation. In this work, the contents of lead (Pb), cadmium (Cd), nickel (Ni), manganese (Mn),...

متن کامل

Determination of Metal Contents in Edible Vegetable Oils Produced in Iran Using Microwave-assisted Acid Digestion

The concentration of heavy metals in vegetable oils is an important criterion for the assessment of oil qualities with regard to freshness, keeping properties, storage and their influence on human nutrition and health. Trace heavy metals in vegetable oils are known to have an effect on the rate of oil oxidation. In this work, the contents of lead (Pb), cadmium (Cd), nickel (Ni), manganese (Mn),...

متن کامل

Extraction and Determination of Heavy Metals Using Silver Coated Magnetic Nanoparticles and Flame Atomic Absorption Spectrometry

A rapid, simple and sensitive magnetic solid phase extraction (MSPE) method was developed for the pre-concentration and determination of copper and cadmium ions. In this study, modified Fe3O4@Ag nanoparticles were synthesized and then ligand 2-isonicotinoyl hydrazine carbodithiolate (ITHCDT) was bonded to silver due to the formation of covalent bond of S-Ag. In this method, copper and cadmium i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 27 1  شماره 

صفحات  -

تاریخ انتشار 1981