Quantitative analysis of liquids from aerosols and microdrops using laser induced breakdown spectroscopy.

نویسندگان

  • Erica M Cahoon
  • Jose R Almirall
چکیده

Laser induced breakdown spectroscopy (LIBS) is shown to be capable of low volume (90 pL) quantitative elemental analysis of picogram amounts of dissolved metals in solutions. Single-pulse and collinear double-pulse LIBS were investigated using a 532 nm dual head laser coupled to a spectrometer with an intensified charge coupled device (CCD) detector. Aerosols were produced using a micronebulizer, conditioned inside a concentric spray chamber, and released through an injector tube with a diameter of 1 mm such that a LIBS plasma could be formed ~2 mm from the exit of the tube. The emissions from both the aerosols and a single microdrop were then collected with a broadband high resolution spectrometer. Multielement calibration solutions were prepared, and continuing calibration verification (CCV) standards were analyzed for both aerosol and microdrop systems to calculate the precision, accuracy, and limits of detection for each system. The calibration curves produced correlation coefficients with R(2) values > 0.99 for both systems. The precision, accuracy, and limit of detection (LOD) determined for aerosol LIBS were averaged and determined for the emission lines of Sr II (421.55 nm), Mg II (279.80 nm), Ba II (493.41 nm), and Ca II (396.84 nm) to be ~3.8% RSD, 3.1% bias, 0.7 μg/mL, respectively. A microdrop dispenser was used to deliver single drops containing 90 pL into the space where a LIBS plasma was generated with a focused laser pulse. In the single drop microdrop LIBS experiment, the analysis of a single drop, containing a total mass of 45 pg, resulted in a precision of 13% RSD and a bias of 1% for the Al I (394.40 nm) emission line. The absolute limits of detection of single drop microdrop LIBS for the emission lines Al I (394.40 nm) and Sr II (421.5 nm) were approximately 1 pg, and Ba II (493.41 nm) produced an absolute detection limit of approximately 3 pg. Overall, the precision, accuracy, and absolute LOD determined for single microdrop LIBS resulted in a typical performance of ~14% RSD, 6% bias, and 1 pg for the elements Sr II (421.55 nm), Al I(394.40 nm), Mg II (279.80), and Ba II(493.41 nm).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of self-absorption correction using internal reference on determining heavy metals concentration by laser induced breakdown spectroscopy

The identification and concentration of heavy metals, which may be so harmful for the body, is determined by the method of calibration-free laser-induced breakdown spectroscopy using a special strategy. First, the plasma temperature is obtained using the Boltzmann plot. Then, a line with an inappreciable self-absorption is considered for each element as the reference. The modified intensities o...

متن کامل

Laser Induced Breakdown Spectroscopy

Laser-induced breakdown spectroscopy (LIBS) is a powerful analytical technique that can be used for the detection and characterization of materials. In LIBS, a focused laser beam is used to generate a plasma plume on the surface of solid and liquid samples or inside the sample volume of gases, liquids, and aerosols. Each excited atom in the plasma emits a unique set of spectral lines, particula...

متن کامل

Optical Opacity of Laser Induced Plasma in Distilled Water with NaCl and TiO2 Nanoparticles Impurities

In this paper, the dynamic behavior of laser induced optical breakdown in impure water was studied by using a pump- probe technique. The plasma was induced by a 1064 nm Nd:YAG laser pulse (with pulse duration ~10 ns) in distilled water with two types of impurities: (I) a solution (highly diluted salt water as a conductor) and (II) a colloidal (TiO2 in colloidal nanoparticle form as a dielectric...

متن کامل

Calibration free laser-induced breakdown spectroscopy of oxide materials

a r t i c l e i n f o Keywords: Calibration free laser-induced breakdown spectroscopy (CF-LIBS) Multi-element analysis Oxides The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration ar...

متن کامل

Analysis by laser-induced breakdown spectroscopy of complex solids, liquids, and powders with an echelle spectrometer.

One of the most promising approaches to laser-induced breakdown spectroscopy (LIBS) experiments involves the use of an echelle spectrometer coupled with an intensified CCD. Even if drawbacks remain with its use, the echelle spectrometer facilitates a multielemental analysis that is more rapid than can be obtained with the more-conventional Czerny-Turner spectrometer and, moreover, does not sacr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 84 5  شماره 

صفحات  -

تاریخ انتشار 2012