Evaluation and interconversion of various indicator PCB schemes for ∑PCB and dioxin-like PCB toxic equivalent levels in fish.

نویسندگان

  • Nilima Gandhi
  • Satyendra P Bhavsar
  • Eric J Reiner
  • Tony Chen
  • Dave Morse
  • George B Arhonditsis
  • Ken G Drouillard
چکیده

Polychlorinated biphenyls (PCBs) remain chemicals of concern more than three decades after the ban on their production. Technical mixture-based total PCB measurements are unreliable due to weathering and degradation, while detailed full congener specific measurements can be time-consuming and costly for large studies. Measurements using a subset of indicator PCBs (iPCBs) have been considered appropriate; however, inclusion of different PCB congeners in various iPCB schemes makes it challenging to readily compare data. Here, using an extensive data set, we examine the performance of existing iPCB3 (PCB 138, 153, and 180), iPCB6 (iPCB3 plus 28, 52, and 101) and iPCB7 (iPCB6 plus 118) schemes, and new iPCB schemes in estimating total of PCB congeners (∑PCB) and dioxin-like PCB toxic equivalent (dlPCB-TEQ) concentrations in sport fish fillets and the whole body of juvenile fish. The coefficients of determination (R(2)) for regressions conducted using logarithmically transformed data suggest that inclusion of an increased number of PCBs in an iPCB improves relationship with ∑PCB but not dlPCB-TEQs. Overall, novel iPCB3 (PCB 95, 118, and 153), iPCB4 (iPCB3 plus 138) and iPCB5 (iPCB4 plus 110) presented in this study and existing iPCB6 and iPCB7 are the most optimal indicators, while the current iPCB3 should be avoided. Measurement of ∑PCB based on a more detailed analysis (50+ congeners) is also overall a good approach for assessing PCB contamination and to track PCB origin in fish. Relationships among the existing and new iPCB schemes have been presented to facilitate their interconversion. The iPCB6 equiv levels for the 6.5 and 10 pg/g benchmarks of dlPCB-TEQ05 are about 50 and 120 ng/g ww, respectively, which are lower than the corresponding iPCB6 limits of 125 and 300 ng/g ww set by the European Union.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Composition of dioxin-like PCBs in fish: an application for risk assessment.

It is widely accepted that a congener-specific analysis of polychlorinated biphenyls (PCBs), rather than traditional Aroclor equivalent total PCB analysis, is required for risk assessment. This is based on the fact that environmental processes alter the original distribution of PCB congeners in Aroclors and that toxicity varies considerably among the congeners with dioxin-like PCBs (dl-PCBs) ge...

متن کامل

Dioxin-like PCBs in the environment-human exposure and the significance of sources.

Dioxin-like PCBs represent an important component of the Sigma-TEQ in many environmental media. Specifically, in animal produce and in fish PCBs dominate the Sigma-TEQ ingested by humans. This in turn leads to high background body burdens in humans with PCB-TEQ greater than that associated with PCDD/Fs. High fish consumers are apparently subject to elevated TEQ exposure from dioxin-like PCBs. T...

متن کامل

Contribution of PCB exposure from fish consumption to total dioxin-like dietary exposure.

Polychlorinated biphenyls (PCB) are the second greatest cause of fish advisories, and are often the greatest contributors to dioxin-like toxic equivalency (TEQ) in fish and seafood. Because fish consumption is associated with both contaminant risks and health benefits, incremental health risks from PCBs in fish should be considered within the context of overall TEQ associated dietary risk to en...

متن کامل

Assessing Fisheries as Vectors for Toxic

As part of an environmental health study of northwest Florida, we conducted an initial screening level assessment of contaminants in blue crabs (Callinectes sapidus) and oysters (Crassostrea virginica) collected in bays and bayous in the Pensacola, FL area. Tissue samples were analyzed for mercury, arsenic, cadmium, chromium, copper, lead, nickel, selenium, tin, zinc, 17 dioxin/furan compounds,...

متن کامل

Polychlorinated biphenyl levels in the tissues of exposed and nonexposed humans.

Polychlorinated biphenyls (PCBs) are synthetic chemicals, manufactured in volume from about 1929 to the 1970s. Environmental contamination by PCBs has been documented in various substances, including human tissue. PCBs have been measured in human tissue by a variety of analytical methods. PCB levels have been reported as an approximation of total PCB content expressed in terms of a commercial m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science & technology

دوره 49 1  شماره 

صفحات  -

تاریخ انتشار 2015