Combined supine and prone quantitative myocardial perfusion SPECT: method development and clinical validation in patients with no known coronary artery disease.

نویسندگان

  • Hidetaka Nishina
  • Piotr J Slomka
  • Aiden Abidov
  • Shunichi Yoda
  • Cigdem Akincioglu
  • Xingping Kang
  • Ishac Cohen
  • Sean W Hayes
  • John D Friedman
  • Guido Germano
  • Daniel S Berman
چکیده

UNLABELLED Acquisition in the prone position has been demonstrated to improve the specificity of visually analyzed myocardial perfusion SPECT (MPS) for detecting coronary artery disease (CAD). However, the diagnostic value of prone imaging alone or combined acquisition has not been previously described using quantitative analysis. METHODS A total of 649 patients referred for MPS comprised the study population. Separate supine and prone normal limits were derived from 40 males and 40 females with a low likelihood (LLk) of CAD using a 3 average-deviation cutoff for all pixels on the polar map. These limits were applied to the test population of 369 consecutive patients (65% males; age, 65 +/- 13 y; 49% exercise stress) without known CAD who had diagnostic coronary angiography within 3 mo of MPS. Total perfusion deficit (TPD), defined as a product of defect extent and severity scores, was obtained for supine (S-TPD), prone (P-TPD), and combined supine-prone datasets (C-TPD). The angiographic group was randomly divided into 2 groups for deriving and validating optimal diagnostic cutoffs. Normalcy rates were validated in 2 additional groups of consecutive LLk patients: unselected patients (n = 100) and patients with body mass index >30 (n = 100). RESULTS C-TPD had a larger area under the receiver-operating-characteristic (ROC) curve than S-TPD or P-TPD for identification of stenosis >or=70% (0.86, 0.88, and 0.90 for S-TPD, P-TPD, and C-TPD, respectively; P < 0.05). In the validation group, sensitivity for P-TPD was lower than for S- or C-TPD (P < 0.05). C-TPD yielded higher specificity than S-TPD and a trend toward higher specificity than P-TPD (65%, 83%, and 86% for S-, P-, and C-TPD, respectively, P < 0.001; vs. S-TPD and P = 0.06 vs. P-TPD). Normalcy rates for C-TPD were higher than for S-TPD in obese LLk patients (78% vs. 95%, P < 0.001). CONCLUSION Combined supine-prone quantification significantly improves the area under the ROC curve and specificity of MPS in the identification of obstructive CAD compared with quantification of supine MPS alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gated 99mTc-MIBI myocardial perfusion SPECT in patients with right bundle branch block but without evidence of coronary artery disease

Introduction: We aimed to investigate the effect of right bundle branch block (RBBB) on perfusion and functional parameters in dipyridamole stress/rest Tc99m-MIBI gated myocardial perfusion SPECT (GSPECT) which may be helpful in interpretation of myocardial perfusion imaging. Methods: We studied 73 patients with low pre-test likelihood of coronary artery disease in two groups:  38 patients wit...

متن کامل

The prognostic value of stress/rest gated myocardial perfusion SPECT in patients with known or suspected coronary artery disease

Introduction:Gated myocardial perfusion SPECT has diagnostic and prognostic values in coronary artery disease (CAD). We tried to determine prognostic values of the left ventricular perfusion & functional indices as well as transient left ventricular dilation (TID) derived from gated myocardial perfusion SPECT. Methods: 1820patients who underwent gated myo...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Quantitative stress-redistribution thallium-201 SPECT using prone imaging: methodologic development and validation.

Prone 201Tl myocardial perfusion SPECT has been shown to improve left ventricular inferior wall counts compared to supine imaging, thus minimizing diaphragmatic attenuation. Prone SPECT quantitative normal limits were developed and prospectively applied to 36 patients who had coronary angiography. The prone imaging table used had a cut-out under cardiac area which increased the average myocardi...

متن کامل

Relationship between the location of the most severe myocardial perfusion defects, the most severe coronary artery stenosis and the site of subsequent myocardial infarction [Persian]

This study evaluated the relationship between the location of the most severe coronary artery stenosis and the subsequent acute myocardial infarction (AMI). Methods: Of 1590 patients who were admitted with a diagnosis of AMI, we identified 44 patients who had undergone previous myocardial perfusion SPECT. Thirty-one of these patients also had previous coronary angiography. The relationshi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 47 1  شماره 

صفحات  -

تاریخ انتشار 2006