Development of a Handheld Side-Stream Breath Analyser for Point of Care Metabolic Rate Measurement
نویسندگان
چکیده
A novel handheld side-stream breath analyser has been developed. The low-cost device offers breath-by-breath measurements of O2, CO2, temperature, relative humidity and gas flow rate. Metabolic rate can be calculated from the inspired and expired gas concentrations; a knowledge of this over a 24 h period can guide calorific intake. The analyser provides easy-to-read results on either a laptop or smart phone. Results for the O2 and CO2 sensors demonstrate the device’s potential for metabolic rate breath analysis. The O2 sensor is not able to follow changes in O2 concentration during the breathing cycle; however, the newly developed affordable and low-power consumption CO2 sensor performs comparably to a bulky, high power consumption commercial device.
منابع مشابه
Comparison of Point of Care (POC) Testing of Glucose by B Braun Glucometer and Hemocue Glucose 201+ Analyser Versus Centralised Testing in Neonatal Intensive Care Unit (NICU).
BACKGROUND Neonatal hypoglycemia is the most common carbohydrate metabolic disturbance seen in case of neonates and especially in preterm neonates. Accurate and rapid determination of hypoglycemia and its prompt treatment is of utmost importance to decrease morbidity and mortality of neonates. AIMS To estimate blood glucose in neonates and test the efficacy of HemoCue Glucose 201+ analyser an...
متن کاملHuman Cardiorespiratory Responses to Resting Water Immersion to the Neck with Changing Body Positions
The aim of the study was to elucidate combined effects of water immersion (WI) and changing body positions on human cardiorespiratory (CR) function in regular swimming pool conditions. Twelve young healthy volunteers (6 females, 6 males) adopted a series of eight 4-min resting body positions on dry land and during WI. CR and gas exchange parameters were measured breath-by-breath by a telemetric...
متن کاملUsing Excess Biomass Sludge Acclimated in Side Stream Partial Nitrification to Evaluation Partial Nitrification and Abrupt Cold Shock Effect in main stream
In this study biomass acclimation in a side stream partial nitrification sequencing batch reactor (SBR) was performed under optimum conditions (T 30ºC, SRT 9± 1 days and hydraulic retention time (HRT) 1.2 day). Excess sludge for solids retention time (SRT) regulation was added to another batch reactor (main stream) which performed under different conditions for partial nitrification evaluation ...
متن کاملPoint of care monitoring of hemodialysis patients with a breath ammonia measurement device based on printed polyaniline nanoparticle sensors.
A device for measuring human breath ammonia was developed based on a single use, disposable, inkjet printed ammonia sensor fabricated using polyaniline nanoparticles. The device was optimized for sampling ammonia in human breath samples by addressing issues such as variations in breath sample volume, flow rate, sources of oral ammonia, temperature and humidity. The resulting system was capable ...
متن کاملDETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD
Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...
متن کامل