Arteriovenous extracorporeal lung assist allows for maximization of oscillatory frequencies: a large-animal model of respiratory distress

نویسندگان

  • Ralf M Muellenbach
  • Julian Kuestermann
  • Markus Kredel
  • Amélie Johannes
  • Ulrike Wolfsteiner
  • Frank Schuster
  • Christian Wunder
  • Peter Kranke
  • Norbert Roewer
  • Jörg Brederlau
چکیده

BACKGROUND Although the minimization of the applied tidal volume (VT) during high-frequency oscillatory ventilation (HFOV) reduces the risk of alveolar shear stress, it can also result in insufficient CO₂-elimination with severe respiratory acidosis. We hypothesized that in a model of acute respiratory distress (ARDS) the application of high oscillatory frequencies requires the combination of HFOV with arteriovenous extracorporeal lung assist (av-ECLA) in order to maintain or reestablish normocapnia. METHODS After induction of ARDS in eight female pigs (56.5 ± 4.4 kg), a recruitment manoeuvre was performed and intratracheal mean airway pressure (mPaw) was adjusted 3 cmH₂O above the lower inflection point (Plow) of the pressure-volume curve. All animals were ventilated with oscillatory frequencies ranging from 3-15 Hz. The pressure amplitude was fixed at 60 cmH₂O. At each frequency gas exchange and hemodynamic measurements were obtained with a clamped and de-clamped av-ECLA. Whenever the av-ECLA was de-clamped, the oxygen sweep gas flow through the membrane lung was adjusted aiming at normocapnia. RESULTS Lung recruitment and adjustment of the mPaw above Plow resulted in a significant improvement of oxygenation (p < 0.05). Compared to lung injury, oxygenation remained significantly improved with rising frequencies (p < 0.05). Normocapnia during HFOV was only maintained with the addition of av-ECLA during frequencies of 9 Hz and above. CONCLUSION In this animal model of ARDS, maximization of oscillatory frequencies with subsequent minimization of VT leads to hypercapnia that can only be reversed by adding av-ECLA. When combined with a recruitment strategy, these high frequencies do not impair oxygenation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical experience with a pumpless extracorporeal lung assist device.

We present three patients with respiratory failure in whom conventional mechanical lung ventilation resulted in unacceptably high levels of carbon dioxide, severe acidosis and high vasopressor requirements. A pumpless arteriovenous extracorporeal carbon dioxide removal device (Novalung) was inserted. Arterial carbon dioxide levels were reduced rapidly with a corresponding increase in pH, reduct...

متن کامل

Editorial III: Remembering awareness.

High survival rate in 122 ARDS patients managed according to a clinical algorithm including extracorporeal membrane oxygenation. beneficial effects of the 'Open Lung Approach' with low distending pressures in acute respiratory distress syndrome. Effect of protective-ventilation strategy on mortality in the acute respiratory distress syndrome. 6 The Acute Respiratory Distress Syndrome Network. V...

متن کامل

A new pumpless extracorporeal interventional lung assist in critical hypoxemia/hypercapnia.

OBJECTIVE Pump-driven extracorporeal gas exchange systems have been advocated in patients suffering from severe acute respiratory distress syndrome who are at risk for life-threatening hypoxemia and/or hypercapnia. This requires extended technical and staff support. DESIGN We report retrospectively our experience with a new pumpless extracorporeal interventional lung assist (iLA) establishing...

متن کامل

Extracorporeal pumpless interventional lung assist in clinical practice: determinants of efficacy.

Respiratory acidosis can become a serious problem during protective ventilation of severe lung failure. A pumpless arteriovenous interventional lung assist (iLA) for extracorporeal carbon dioxide removal has been used increasingly to control critical respiratory situations. The present study sought to evaluate the factors determining the efficacy of iLA and calculate its contribution to gas exc...

متن کامل

Bronchial fistulae in ARDS patients: management with an extracorporeal lung assist device.

Patients with bronchial tree lesions feature, in particular, a high risk for developing bronchial fistulae after surgical repair when the clinical situation is complicated by acute lung injury (ALI)/acute respiratory distress syndrome (ARDS) and mechanical ventilation is needed. The current authors hypothesised that extracorporeal carbon dioxide removal would significantly decrease inspiratory ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Anesthesiology

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2008