Nuclear Gamma Resonance Study of Alloy Systems

ثبت نشده
چکیده

The Ir-Fe and Ir-Ni alloy systems were studied over the whole composition range by means of the nuclear resonance absorption of the 73 keV y-rays of 193Jr and of the 14.4 keV y-rays of 57Fe. The magnetic hyperfine field at the Ir-nuclei in Ir-Ni alloys decreases approximately linearly with the Ir concentration from — 460 kOe at 4.2 K in very dilute alloys to zero at about 20 at.-% Ir. This behaviour is paralleled by the decrease of the magnetic moment per Ni atom as determined from bulk magnetization measurements. The hyperfine fields at both Ir and Fe were measured for the ferromagnetic bcc phase of the Ir-Fe system. They turned out to be virtually independent of concentration with values of about —1400 kOe and — 330 kOe, respectively. Linewidths increasing with the Ir concentration indicate a distribution of hyperfine fields. The fee phase of the Ir-Fe system has been found to be paramagnetic at 4.2 K throughout the range of its existence. The dependence of the hyperfine fields on concentration is discussed in terms of a rigid 3d-band model combined with local shielding. A discussion of the concentration dependence of the 193Ir and 57Fe isomer shifts has to take into account lattice expansion as well as band repopulation effects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

NUCLEAR MAGNETIC RESONANCE STUDY OF THE STRUCTURE OF GLYOXALDIHYDRAZONE

Study of the nuclear magnetic resonance spectra of glyoxaldihydrazone in dimethylsulfoxide and deuterochlorofonn leads to the conclusion that this compound exists predominantly in non-chelate structure

متن کامل

Appropriate energy window width for gamma camera [Persian]

Introduction: Scatter radiation is one of the major sources of error in nuclear medicine data processing. Different methods of scatter correction have been introduced in order to improve the quality of data. However the best method is to avoid recording of scatter photons in acquisition. The only difference between scattered and non-scattered photons is the energy. Pulse height analyzer i...

متن کامل

Gamma scintigraphy in the evaluation of drug delivery systems [Persian]

Gamma-scintigraphy is applied extensively in the development and evaluation of pharmaceutical delivery systems, particularly for monitoring formulations in the gastrointestinal and respiratory tracts. The radiolabelling is generally achieved by the incorporation of an appropriate radionuclide such as technetium-99m or indium-111 into the formulation or by addition of a non-radioactive iso...

متن کامل

Computational study of energetic, stability, and nuclear magnetic resonance of BN nanotube as a nanosensor

Now a day study on boron nitrid nanotubes are in considerable attetion due to their unique properties in different field of science. In this letter, after final optimization, thermodynamic properties analysis, stabilities, electronic structure and nuclear magnetic resonance parameters including σ isotropic and σ anisotropic tensors and asymmetric parameters of 15N and 11B nuclei are calculated....

متن کامل

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013