Radiobiological modeling analysis of the optimal fraction scheme in patients with peripheral non-small cell lung cancer undergoing stereotactic body radiotherapy

نویسندگان

  • Bao-Tian Huang
  • Jia-Yang Lu
  • Pei-Xian Lin
  • Jian-Zhou Chen
  • De-Rui Li
  • Chuang-Zhen Chen
چکیده

This study aimed to determine the optimal fraction scheme (FS) in patients with small peripheral non-small cell lung cancer (NSCLC) undergoing stereotactic body radiotherapy (SBRT) with the 4 × 12 Gy scheme as the reference. CT simulation data for sixteen patients diagnosed with primary NSCLC or metastatic tumor with a single peripheral lesion ≤3 cm were used in this study. Volumetric modulated arc therapy (VMAT) plans were designed based on ten different FS of 1 × 25 Gy, 1 × 30 Gy, 1 × 34 Gy, 3 × 15 Gy, 3 × 18 Gy, 3 × 20 Gy, 4 × 12 Gy, 5 × 12 Gy, 6 × 10 Gy and 10 × 7 Gy. Five different radiobiological models were employed to predict the tumor control probability (TCP) value. Three other models were utilized to estimate the normal tissue complication probability (NTCP) value to the lung and the modified equivalent uniform dose (mEUD) value to the chest wall (CW). The 1 × 30 Gy regimen is recommended to achieve 4.2% higher TCP and slightly higher NTCP and mEUD values to the lung and CW compared with the 4 × 12 Gy schedule, respectively. This regimen also greatly shortens the treatment duration. However, the 3 × 15 Gy schedule is suggested in patients where the lung-to-tumor volume ratio is small or where the tumor is adjacent to the CW.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiobiological modeling of two stereotactic body radiotherapy schedules in patients with stage I peripheral non-small cell lung cancer

This study aims to compare the radiobiological response of two stereotactic body radiotherapy (SBRT) schedules for patients with stage I peripheral non-small cell lung cancer (NSCLC) using radiobiological modeling methods. Volumetric modulated arc therapy (VMAT)-based SBRT plans were designed using two dose schedules of 1 × 34 Gy (34 Gy in 1 fraction) and 4 × 12 Gy (48 Gy in 4 fractions) for 19...

متن کامل

Stereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters

Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...

متن کامل

Impact of Prolonged Fraction Delivery Time Modelling Stereotactic Body Radiation Therapy with High Dose Hypofractionation on the Killing of Cultured ACHN Renal Cell Carcinoma Cell Line

Introduction: Stereotactic body radiotherapy delivers hypofractionated irradiation with high dose per fraction through complex treatment techniques. The increased complexity leads to longer dose delivery times for each fraction. The purpose of this study is to investigate the impact of prolonged fraction delivery time with high-dose hypofractionation on the killing of cultured ACHN cells.Method...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Comparative Analysis of Local Control Prediction Using Different Biophysical Models for Non-Small Cell Lung Cancer Patients Undergoing Stereotactic Body Radiotherapy

PURPOSE The consistency for predicting local control (LC) data using biophysical models for stereotactic body radiotherapy (SBRT) treatment of lung cancer is unclear. This study aims to compare the results calculated from different models using the treatment planning data. MATERIALS AND METHODS Treatment plans were designed for 17 patients diagnosed with primary non-small cell lung cancer (NS...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015