Optic nerve ultrasound for the detection of raised intracranial pressure.
نویسندگان
چکیده
BACKGROUND Optic nerve ultrasonography (ONUS) may help identify raised intracranial pressure (ICP). The optimal optic nerve sheath diameter (ONSD) cut-off for the identification of intracranial hypertension has not been established, with some clinical studies suggesting a higher cut-off than may be expected on the basis of prior laboratory investigation. OBJECTIVE To validate ONUS performed by neurointensivists as a technique for the detection of intracranial hypertension and identify the optimal ONSD criterion for the detection of ICP > 20 mmHg. METHODS Prospective blinded observational study. Patients in the ICU with either external ventricular drains or intraparenchymal ICP monitors at risk for intracranial hypertension were enrolled. The ONSD was measured by neurointensivists at the bedside with simultaneous invasive ICP measurement. An ROC curve was constructed to determine the optimal ONSD for the detection of ICP > 20 mmHg. MEASUREMENTS AND RESULTS A total of 536 ONSD measurements were performed on 65 patients. Diagnoses included subarachnoid hemorrhage, traumatic brain injury, intracerebral hemorrhage, ischemic stroke and brain tumor. ROC curve analysis revealed area under the curve (AUC) = 0.98 (95% CI 0.96-0.99; P < 0.0001 for AUC = 0.5). Optimal ONSD for detection of ICP > 20 mmHg was ≥0.48 cm sensitivity 96% (95% CI 91-99%); specificity 94% (92-96%). Sensitivity of the higher cutoff of ≥0.52 cm proposed by some authors was only 67% (58-75%), with specificity 98% (97-99%). CONCLUSIONS Bedside ONSD measurement, performed by neurointensivists, is an accurate, non-invasive method to identify ICP > 20 mmHg in a heterogeneous group of patients with acute brain injury. ONSD ≥0.48 cm has the greatest accuracy, however, internal validation of ONSD criteria may be required.
منابع مشابه
SCIENTIFIC CORRESPONDENCE Measurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus
Aim: To evaluate the utility of measuring the optic nerve sheath diameter in children with shunted hydrocephalus, suspected of having raised intracranial pressure. Methods: 23 children with shunted hydrocephalus were examined, six had well controlled ICP, 17 however manifested symptoms suggestive of intracranial hypertension. A clinical history was taken from all patients and their parents or c...
متن کاملOptic Nerve Sheath Ultrasound for the Bedside Diagnosis of Intracranial Hypertension: Pitfalls and Potential
Raised intracranial pressure is a complication not just of traumatic brain injury and other acute cerebral insults, but also of a number of general medical conditions. Bedside diagnosis can be difficult; early clinical signs may be misinterpreted, and reliance on cross-sectional imaging studies may further delay diagnosis. Ultrasound is a readily available imaging modality in most critical care...
متن کاملMeasurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus.
AIM To evaluate the utility of measuring the optic nerve sheath diameter in children with shunted hydrocephalus, suspected of having raised intracranial pressure. METHODS 23 children with shunted hydrocephalus were examined, six had well controlled ICP, 17 however manifested symptoms suggestive of intracranial hypertension. A clinical history was taken from all patients and their parents or c...
متن کاملTreatment of upper airway oedema prior to extubation
777 Indian Journal of Anaesthesia | Vol. 60 | Issue 10 | Oct 2016 of raised intracranial pressure: A systematic review and meta‐analysis. Intensive Care Med 2011;37:1059‐68. 7. Rajajee V, Vanaman M, Fletcher JJ, Jacobs TL. Optic nerve ultrasound for the detection of raised intracranial pressure. Neurocrit Care 2011;15:506‐15. 8. Govil D, Srinivasan S. Optic nerve sheath diameter measurement usi...
متن کاملEffect of scuba-diving on optic nerve and sheath diameters
Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated. Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...
متن کاملBrain Trauma Measurement of Optic Nerve Sheath Diameter for the Assessment of Risk of Raised Intracranial Pressure
Raised intracranial pressure (ICP) is associated with poor outcome after brain injury, but is difficult to detect without invasive devices. As a part of the central nervous system, the optic nerve is surrounded by a dural sheath, and the subarachnoid space surrounding the optic nerve is subject to the same pressure changes as the intracranial compartment. Distension of the optic nerve sheath re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Neurocritical care
دوره 15 3 شماره
صفحات -
تاریخ انتشار 2011