Comparison of detrending methods for optimal fMRI preprocessing.

نویسندگان

  • Jody Tanabe
  • David Miller
  • Jason Tregellas
  • Robert Freedman
  • Francois G Meyer
چکیده

Because of the inherently low signal to noise ratio (SNR) of fMRI data, removal of low frequency signal intensity drift is an important preprocessing step, particularly in those brain regions that weakly activate. Two known sources of drift are noise from the MR scanner and aliasing of physiological pulsations. However, the amount and direction of drift is difficult to predict, even between neighboring voxels. Further, there is no concensus on an optimal baseline drift removal algorithm. In this paper, five voxel-based detrending techniques were compared to each other and an auto-detrending algorithm, which automatically selected the optimal method for a given voxel time-series. For a significance level of P < 10(-6), linear and quadratic detrending moderately increased the percentage of activated voxels. Cubic detrending decreased activation, while a wavelet approach increased or decreased activation, depending on the dataset. Spline detrending was the best single algorithm. However, auto-detrending (selecting the best algorithm or none, if detrending is not useful) appears to be the most judicious choice, particularly for analyzing fMRI data with weak activations in the presence of baseline drift.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the Performance of ICA Algorithm for fMRI Simulated Data Analysis Using Temporal and Spatial Filters in the Preprocessing Phase

Introduction: The accuracy of analyzing Functional MRI (fMRI) data is usually decreases in the presence of noise and artifact sources. A common solution in for analyzing fMRI data having high noise is to use suitable preprocessing methods with the aim of data denoising. Some effects of preprocessing methods on the parametric methods such as general linear model (GLM) have previously been evalua...

متن کامل

Optimizing preprocessing and analysis pipelines for single-subject fMRI. I. Standard temporal motion and physiological noise correction methods.

Subject-specific artifacts caused by head motion and physiological noise are major confounds in BOLD fMRI analyses. However, there is little consensus on the optimal choice of data preprocessing steps to minimize these effects. To evaluate the effects of various preprocessing strategies, we present a framework which comprises a combination of (1) nonparametric testing including reproducibility ...

متن کامل

Optimizing Preprocessing and Analysis Pipelines for Single-Subject fMRI: 2. Interactions with ICA, PCA, Task Contrast and Inter-Subject Heterogeneity

A variety of preprocessing techniques are available to correct subject-dependant artifacts in fMRI, caused by head motion and physiological noise. Although it has been established that the chosen preprocessing steps (or "pipeline") may significantly affect fMRI results, it is not well understood how preprocessing choices interact with other parts of the fMRI experimental design. In this study, ...

متن کامل

Detection and detrending in fMRI data analysis.

This article addresses the impact that colored noise, temporal filtering, and temporal detrending have on the fMRI analysis situation. Specifically, it is shown why the detection of event-related designs benefit more from pre-whitening than blocked designs in a colored noise structure. Both theoretical and empirical results are provided. Furthermore, a novel exploratory method for producing dri...

متن کامل

A Preprocessing Technique to Investigate the Stability of Multi-Objective Heuristic Ensemble Classifiers

Background and Objectives: According to the random nature of heuristic algorithms, stability analysis of heuristic ensemble classifiers has particular importance. Methods: The novelty of this paper is using a statistical method consists of Plackett-Burman design, and Taguchi for the first time to specify not only important parameters, but also optimal levels for them. Minitab and Design Expert ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2002