Compliance-dependent load allocation between sensing versus non-sensing portions of a sheet-array contact stress sensor.
نویسندگان
چکیده
Piezoresistive array pressure sensors are widely used in orthopaedic research to determine contact stress distributions across articular joint surfaces. Experience with such sensors has shown there can be inaccuracies in how the sensor perceives applied load, depending on the material stiffnesses between which it is compressed experimentally, versus in calibration. A study was undertaken to quantify the relationship between load perception of one such sensor design (Tekscan) and the stiffness of the materials between which it is compressed. A three-dimensional finite element model of a 3x3 sensel portion of the sensing matrix was formulated, along with a layer of compression test material on each side of the sensor. The elastic modulus of the test material was varied across the range representative of cartilage (12 MPa) to hard plastic (10 GPa). Using the computed contact pressure results between contacting surfaces of the sensor layers, the percentage of load passing through the active conductor intersections was determined. The results revealed that with increase of the elastic modulus of the material between which the sensor was compressed, the percentage of load on the active conductor intersections increased monotonically. The highest sensitivity of perceived loading to test material modulus (0.1%/MPa) was seen at the low end of the modulus range. The more compliant the test material, the more the sensor layers conformed around each other's geometric incongruities, the larger the true contact areas, and the higher the fraction of the total load that passed through the intermediate (non-sensing) regions between the conductors.
منابع مشابه
Strain and Damage Sensing Property of Self-compacting Concrete Reinforced with Carbon Fibers
Present paper investigated the strain and damage sensing property on concrete cubes embedded with carbon fibers. Concrete cubes of dimension 150 mm have been casted with different concentration of carbon fibers to study the strain and damage sensing property under cyclic loading that can be further used for health monitoring as non-destructive testing (NDT) approach. All the specimens were test...
متن کاملA Novel Inverse Solution of Contact Force Based on a Sparse Tactile Sensor Array
High-density tactile sensing has been pursued for humanoid robotic hands to obtain contact force information while the elastomer skin cover is traditionally considered to impair the force discrimination. In this work, we try to utilize the diffusion effect of the elastomer cover to identify an arbitrary contact force load just based on a sparse tactile sensor array. By numerical analysis, we pr...
متن کاملA new sensor for measurement of dynamic contact stress in the hip.
Various techniques exist for quantifying articular contact stress distributions, an important class of measurements in the field of orthopaedic biomechanics. In situations where the need for dynamic recording has been paramount, the approach of preference has involved thin-sheet multiplexed grid-array transducers. To date, these sensors have been used to study contact stresses in the knee, shou...
متن کاملCouple Stress Effect on Micro/Nanocantilever-based Capacitive Gas Sensor
Micro/nanocantilevers have been employed as sensors in many applications including chemical and biosensing. Due to their high sensitivity and potential for scalability, miniature sensing systems are in wide use and will likely become more prevalent in micro/nano-electromechanical systems (M-NEMSs). This paper is mainly focused on the use of sensing systems that employ micro/nano-size cantilever...
متن کاملProbabilistic Damage Detection Based on Large Area Electronics Sensing Sheets
Reliable early-stage damage detection and characterization requires continuous sensing over large areas of structure. The limitations with current sensing technologies lies in the fact that they either have high cost and insufficient spatial resolution, or rely on complex algorithms that are challenged by varying environmental and loading conditions. This paper addresses the need for direct sen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Iowa orthopaedic journal
دوره 29 شماره
صفحات -
تاریخ انتشار 2009