A Method for the Observation of the Primo Vascular System in the Thoracic Duct of a Rat
نویسندگان
چکیده
Even though the primo vascular system (PVS) has been observed in large caliber lymph vessels by several independent teams, the presence of the PVS in the thoracic duct has been reported by only one team, probably because reproducing the experiment is technically difficult. This brief report presents a new, relatively straightforward method, which is a simple modification of the previous method of dye injection into the lumbar node, to observe the PVS in a thoracic duct of a rat by injecting Alcian blue into the renal node. When this new method was applied to a rat, the branching of the primo vessel in the thoracic duct was clearly displayed. Thus, this new method is expected to extend the network of the PVS from abdominal lymph ducts to thoracic ones.
منابع مشابه
Observation of the Primo Vessel Approaching the Axillary Lymph Node with the Fluorescent Dye, DiI
The primo vascular system (PVS) floating in lymph fluid has mostly been observed in large caliber ducts around the caudal vena cava and the thoracic duct of rabbits, rats, and mice. But the PVS has not been traced up to the lymph nodes. It has not been established whether the PVS leaves the lymph vessel through the lymph vessel wall or it enters the lymph nodes. Therefore, observing the PVS ent...
متن کاملValidation of treatment planning system using simulation PRIMO code.
Introduction: In radiation therapy, in order to double-check the dosimetric results of the main treatment planning system (TPS), a distinct TPS, with few capacitances in terms of contouring and a variety of dose calculation algorithms is used. This system has the capability to double check the planification and the accurate prediction of dose distribution in order to be ensured...
متن کاملMechanical activity of isolated aorta strips after prolonged exposure to low frequency electromagnetic fields and its interaction with the cholinergic and adrenergic systems in male rat
Introduction: Public concern about the potential effects of electromagnetic field (EMF) on human health is increased by progressive usage of electrical devices in modern life. The aim of this study was to investigate the effect of prolonged exposure to low frequency EMF on the mechanical activity of isolated thoracic aorta strips in rats. Methods: Fourteen male rats were randomly allocated into...
متن کاملObservation of a Flowing Duct in the Abdominal Wall by Using Nanoparticles.
The primo vascular system (PVS) is being established as a circulatory system that corresponds to acupuncture meridians. There have been two critical questions in making the PVS accepted as a novel liquid flowing system. The first one was directly to show the flow of liquid in PVS and the second one was to explain why it was not observed in the conventional histological study of animal tissues. ...
متن کاملMonte Carlo Simulation of Prostate Intensity Modulated Radiotherapy Using PRIMO Software: A Feasibility Study
Introduction: Nowadays Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Must of the Monte Carlo software cannot simulate the IMRT procedures due to inability of these soft wares to simulate the multi leaf collimator (MLC) positions or movements. A new user-friendly software based on the PENELOPE Monte Carlo code named PRIMO was published...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2013 شماره
صفحات -
تاریخ انتشار 2013