Reliability of shoulder range of motion comparing a goniometer to a digital level.
نویسندگان
چکیده
The clinical use of digital levels, for joint measurement, may be a viable alternative to standard goniometry. The purpose of this study was to determine the intra- and intertester reliability of a construction grade digital level compared to the standard universal goniometer for measurements for active assisted shoulder range of motion (ROM). Two experienced physical therapists measured shoulder flexion, external rotation (ER), and internal rotation (IR) ROM bilaterally, on two different occasions, in 20 patients (9 males, 11 females, 18-79 years old) with unilateral shoulder pathology, using a goniometer and a digital level. Relative reliability was assessed by using intraclass correlation coefficients (ICC), and absolute reliability was assessed by using 95% limits of agreement (LOA). Intratester ICCs ranged from 0.91 to 0.99, and LOA ranged from 3 degrees to 9 degrees for measurements made with the goniometer and digital level. Intertester ICCs ranged from 0.31 to 0.95, and LOA ranged from 6 degrees to 25 degrees . For the comparison of goniometric vs. digital level ROM, ICCs ranged from 0.71 to 0.98. ER and IR ROM were 3-5 degrees greater for the digital level than the goniometer (p < 0.01). Goniometric vs. digital level LOA ranged from 6 degrees to 11 degrees for shoulder flexion. Both measurement techniques had excellent intratester reliability, but for intertester reliability ICCs were 20% lower and LOA were 2.3 times higher than intratester values. Reliability estimates were similar between the digital level and the goniometer. However, because glenohumeral rotation was 3-5 degrees greater for the digital level than the goniometer (systematic error), the two methods cannot be used interchangeably. On the basis of the average intratester LOA for the goniometer and the digital level, a change of 6-11 degrees is needed to be certain that true change has occurred. For comparison of measures made by two different therapists, a change is of 15 degrees is required to be certain a true change has occurred. A digital level can be used to reliably measure shoulder ROM but should not be used interchangeably with a standard goniometer.
منابع مشابه
Comparing the Effects of Electroacupuncture and Low Level Laser on Treatment of Frozen Shoulder Disease: A Single Blind Clinical Trial
Background and Objectives: Frozen shoulder or adhesive capsulitis of the shoulder is one of the most common diseases of the shoulder. In this diseases capsule of shoulder is stiff, shortening, adhesive, painful and frozen. The aim of this study was to determine and compare the effect of electroacupuncture (EA) and Low Level Laser Therapy (LLLT) on treatment of frozen shoulder. Material and Met...
متن کاملTest-retest reliability of an active range of motion test for the shoulder and hip joints by unskilled examiners using a manual goniometer.
[Purpose] The purpose of this study was to analyze test-retest reliability of an active range of motion test using a manual goniometer by unskilled examiners. [Subjects and Methods] Active range of motion was measured in 30 students attending U university (4 males, 26 females). Range of motion during flexion and extension of the shoulder and hip joints were measured using a manual goniometer. [...
متن کاملComparison of the Kyphosis Angle, Position, Muscles Strength and Range of Motion of Shoulders in Volleyball Players with and without Shoulder Impingement Syndrome
Purpose: This case-control study aimed at comparing the kyphosis angle, position of the shoulder, the strength of rotator cuff muscles, and the range of shoulder motions in volleyball players with and without impingement syndrome. Methods: The participants were 22 male professional volleyball players with at least 5 years of training experience. Eleven volleyball players with impingement syndr...
متن کاملThe Effect of Static Magnet Therapy on Pain-Free Shoulder Passive Range of Motion in Patients with Shoulder Subluxation after Stroke: A Randomized Clinical Trial
Introduction: One of the stroke complications is hemiplegia, which can cause subluxation of the shoulder joint and reduce the passive range of motion of the affected shoulder, resulting in limited movement. This study aimed to evaluate the effect of static magnet therapy on pain-free shoulder passive range of motion in patients with shoulder subluxation after stroke. Methods: This clinical tri...
متن کاملThe Reliability and Concurrent Validity of Digital Inclinometer, Smartphone Applications, and the Cervical Range of Motion Device for Measuring the Cervical Range of Motion
Objectives: Changes in the Range of Motion (ROM) are essential criteria in determining the severity of spinal disorders and could be effective in predicting pain progression. Instruments to measure the ROM are costly and unavailable in most therapy settings. While there is a tendency in therapists to use their smartphones instead, there is no report to measure the suitability of smartphones to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiotherapy theory and practice
دوره 26 5 شماره
صفحات -
تاریخ انتشار 2010