Evaluation of the Telomeric Repeat Amplification Protocol (TRAP) Assay for Telomerase as a Diagnostic Modality in Recurrent Bladder Cancer1
نویسندگان
چکیده
There is a need for the identification of an accurate test for the detection of recurrent bladder cancer. In this study, we evaluate the telomeric repeat amplification protocol (TRAP) assay for detection of tebomerase as a potential new method for bladder cancer detection and compare it to voided urine cytology. A urine sample and a bladder wash were obtained from 63 patients with a history of bladder cancer. Cytological evaluation was performed on voided urine, and the TRAP assay was performed on voided urine and bladder wash. The overall clinical sensitivity of the TRAP assay, as defined by the ability to identify correctly the patients with pathologically confirmed bladder cancer, was 35% in voided urine and 50% in bladder wash, whereas the overall clinical sensitivity of voided urine cytology was 71 %. The sensitivity of voided urine cytology for the papillary and noninvasive tumors (Ta) was 50%, compared to 92% for the superficially invasive tumors (T1), 62% for the muscle-invasive tumors (T2#{247}), and 100% for the high-grade flat carcinoma in situ (T1,). The clinical sensitivity of the TRAP assay using voided urine was 46% for Ta 50% for T1, 18% for T2 , and 20% for T1,. The sensitivity of the TRAP assay in Ta disease was similar to that of cytology (50% for cytology versus 46% for the TRAP assay). There was a strong association between Received 1/2 1/97; revised 5/5/97; accepted 5/16/97. The costs of publication of this article were defrayed in part by the payment of page charges. This article must therefore be hereby marked advertisement in accordance with 18 U.S.C. Section 1734 solely to indicate this fact. I Supported in part by National Cancer Institute Grant 47538, NIH Grant U 9 CA 67842 (to M. A. S. M.), and the Gar Reichman Fund of the Cancer Research Institute (to M. A. S. M.). G. D. is the recipient of an American Cancer Society Career Development Award. 2 To whom requests for reprints should be addressed, at Urology Service, Department of Surgery, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10021. Phone: (212) 639-8131; Fax: (2 12) 7 17-3175; E-mail: [email protected]. the total number of exfoliated malignant cells and the sensitivity of the assay. The sensitivity of the TRAP assay in bladder washes was 44% for Ta 67% for T1, 46% for T2 , and 43% for T1,. The TRAP assay is reproducible, highly specific, and not dependent on the expertise of the cytopathologist. These results suggest that this assay should be further investigated as a diagnostic tool for bladder cancer.
منابع مشابه
مقایسه حساسیت و ویژگی سیتولوژی و اندازه گیری فعالیت تلومراز در ادرار به روش Trap Assay جهت تشخیص سرطان مثانه
Introduction & Objective : Telomerase is a reverse transcriptase enzyme that is required in immortalized cancer cells. Early detection of telomerase activity in tumors particularly in bladder cancer is promising. The aim of this study was to compare specificity and sensitivity between cytology and telomerase activity in diagnosis of bladder cancer. Materials & Methods : This study was a case...
متن کاملErythrocyte folate does not accurately reflect folate status in sickle cell disease.
bladder washings of patients with recurrent urothelial cell carcinomas [Technical Brief]. Clin Chem 2000;46:2003–7. 5. de Kok JB, Zendman AJ, van de Locht LT, Ruers TJM, van Muijen GN, Mensink E, Swinkels DW. Real-time hTERT quantification: a promising telomerase-associated tumor marker. Lab Invest 1999;79:911–2. 6. Dalbagni G, Han W, Zhang ZF, Cordon CC, Saigo P, Fair WR, et al. Evaluation of ...
متن کاملAdvances in quantification and characterization of telomerase activity by the telomeric repeat amplification protocol (TRAP)
The telomeric repeat amplification protocol (TRAP) assay has been used to test telomerase activity in numerous cancer specimens. We describe primers, controls and quantification methods for the TRAP assay to accurately measure the level of telomerase activity in clinical samples. The assay is reliable and reproducible in routine analyses and can be used to estimate the processivity of telomeras...
متن کاملIncreased sensitivity and reproducibility of TRAP assay by avoiding direct primers interaction.
Telomeric Repeat Amplification Protocol (TRAP) is a sensitive procedure to measure telomerase activity in small samples of cell or tissue extracts. Due to the strict correlation between high levels of telomerase activity and neoplastic transformation, TRAP assay could provide an important diagnostic marker of malignancy. Although the original TRAP assay is very sensitive and some improvements h...
متن کاملTelomeric repeat amplification, without shortening or lengthening of the telomerase products: a method to analyze the processivity of telomerase enzyme.
The Telomeric Repeat Amplification Protocol (TRAP) and its modified versions (including ours, TP-TRAP) change the size and/or the ratio of the telomerase products in the amplification stage of the assay. Based on our recently published method we developed a new TRAP. This method ensures that the number of telomeric repeats present in the original telomerase products does not change on PCR ampli...
متن کامل