Real-time myocardium segmentation for the assessment of cardiac function variation

نویسندگان

  • Fabian Zoehrer
  • Markus Huellebrand
  • Teodora Chitiboi
  • Thekla Oechtering
  • Malte Sieren
  • Jens Frahm
  • Horst K. Hahn
  • Anja Hennemuth
چکیده

Recent developments in MRI enable the acquisition of image sequences with high spatio-temporal resolution. Cardiac motion can be captured without gating and triggering. Image size and contrast relations differ from conventional cardiac MRI cine sequences requiring new adapted analysis methods. We suggest a novel segmentation approach utilizing contrast invariant polar scanning techniques. It has been tested with 20 datasets of arrhythmia patients. The results do not differ significantly more between automatic and manual segmentations than between observers. This indicates that the presented solution could enable clinical applications of real-time MRI for the examination of arrhythmic cardiac motion in the future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lipopolysaccharide Induced Activation of Toll Like Receptor 4 in Isolated Rat Heart Suggests a Local Immune Response in Myocardium

Background: Myocardial dysfunction is one of the major complications in patients with sepsis where there is a relationship between the blood level of cytokines and the onset of myocardial depression. In many cases of sepsis, the presence of Lipopolysaccharide (LPS) has been established. LPS Binding Protein (LBP) bound endotoxin is recognized by CD14/toll-like receptor-4 (TLR4) complexes in inna...

متن کامل

Final Report: Automated Semantic Segmentation of Volumetric Cardiovascular Features and Disease Assessment

Cardiac magnetic resonance imaging provides high spatial resolution, enabling improved extraction of important functional and morphological features for cardiovascular disease staging. Segmentation of the heart in cardiac cine sequencing is clinically used for cardiac function assessment. We present a method that curtails the expense and observer bias of manual cardiac evaluation by combining s...

متن کامل

Variational Segmentation Framework in Prolate Spheroidal Coordinates for 3D Real-Time Echocardiography

This paper presents a new formulation of a deformable model segmentation in prolate spheroidal coordinates for segmentation of 3D cardiac echocardiography data. The prolate spheroidal coordinate system enables a representation of the segmented surface with descriptors specifically adapted to the "ellipsoidal" shape of the ventricle. A simple data energy term, based on gray-level information, gu...

متن کامل

Quantitative Comparison of SPM, FSL, and Brainsuite for Brain MR Image Segmentation

Background: Accurate brain tissue segmentation from magnetic resonance (MR) images is an important step in analysis of cerebral images. There are software packages which are used for brain segmentation. These packages usually contain a set of skull stripping, intensity non-uniformity (bias) correction and segmentation routines. Thus, assessment of the quality of the segmented gray matter (GM), ...

متن کامل

An Improved Automatic EEG Signal Segmentation Method based on Generalized Likelihood Ratio

It is often needed to label electroencephalogram (EEG) signals by segments of similar characteristics that are particularly meaningful to clinicians and for assessment by neurophysiologists. Within each segment, the signals are considered statistically stationary, usually with similar characteristics such as amplitude and/or frequency. In order to detect the segments boundaries of a signal, we ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017