Testing and Development of the P10 Scintillator for the Focal Plane Detector: Delving into the Depths of Plastic

نویسنده

  • Maria Teresa Herd
چکیده

The P10 scintillator is a component of the Focal Plane Detector being developed at Michigan State University. The scintillator will stop and determine the energy of incoming isotopes. The project focused on testing and calibration of the thick scintillator. Photomultiplier tubes were tested then coupled to the scintillator. The PMTs were then gain matched. Tests were run to determine the position sensitivity of the scintillator and test the response of the PMTs. The scintillator was found to be position sensitive.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy Reconstruction with the Sweeper Magnet Focal Plane Detector

The Sweeper Magnet Focal Plane Detector project is a collaboration of the National High Magnetic Field Laboratory (NHMFL) at Florida State University and the National Superconducting Cyclotron Laboratory (NSCL) at Michigan State University. The NHMFL will construct the Sweeper Magnet, a large C-type magnet necessary for the bending of rigid nuclear beams. The NSCL will build the Focal Plane Det...

متن کامل

Investigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code

Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...

متن کامل

Optical simulation and experimental measurement of gamma ray energy spectrum of plastic scintillators with different sizes

The application of large plastic scintillators is widely increasing in the different areas of industry, medicine and security due to technical and economic advantages. One of the main disadvantages of these detectors is the unknown position of Compton edge at gamma ray spectrum. In this research, GEANT4/GATE code has been used to simulate the gamma ray spectrum for different volumes of large pl...

متن کامل

Calculations of absorbed dose and energy dependent of small-scale dosimeters for photons beam therapy

In this study, the energy dependency for dosimeters of air ionization chambers, lithium fluoride, silicon and plastic scintillator has been studied using the MCNPX Monte Carlo simulation code and simulated for gamma energy in the range of radiotherapy energy. The simulation results show that the response of each of the dosimeters for gamma photon beams in the energy range of 0.2 to 20 MeV varie...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002