Tilt-table testing as a predictor of + GZ tolerance.

نویسندگان

  • E Zawadzka-Bartczak
  • L Kopka
چکیده

BACKGROUND G-tolerance assessment is an essential element of both military pilot and pilot candidate evaluation. AIMS Attempt at prediction of individual relaxed + Gz tolerance on the basis of head-up tilt (HUT) testing. SETTINGS AND DESIGN In two stages, 20 healthy men at the mean age 21.5 years took part in this study. The first stage, a 45 min, HUT test was performed using the Westminster protocol. During the second stage each underwent a centrifuge evaluation in response to gradual onset rate profiles. METHODS AND MATERIAL In each subject, heart rate (HR) and blood pressure (BP) before and at 2, 15 and 45 min of the tilt-test were recorded. The gravity-load centrifuge (GOR) studies were carried out [following the standard GOR programme, at 0.1 G%divide;s rate of gravity load increase until the gravity load tolerance limit (loss of peripheral vision) was reached]. STATISTICAL ANALYSIS USED Relationships between variables were explored using Kendall's tau-B correlation coefficient. The critical P-level was one-tailed 0.05. RESULTS In four of 20 subjects (20%), vasovagal syncope occurred during the tilt test. G-level tolerance of this group (of +Gz accelerations) lay in the range from +4 to +8.1 Gz, (+5.72 ? 0.86 Gz average) and was comparable to the group without syncope. Loss of consciousness did not occur in any subjects during the centrifuge test. No statistically significant correlation was observed between HR and BP during tilt test and tolerance to +Gz accelerations. CONCLUSIONS The result of tilt testing, carried out according to the Westminster protocol, was not useful in predicting individual tolerance to +Gz gravity loads.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hypotensive effect of push-pull gravitational stress occurs after autonomic blockade.

The "push-pull" effect denotes the reduced tolerance to +Gz (hypergravity) when +Gz stress is preceded by exposure to hypogravity, i.e., fractional, zero, or negative Gz. Previous studies have implicated autonomic reflexes as a mechanism contributing to the push-pull effect. The purpose of this study was to test the hypothesis that nonautonomic mechanisms can cause a push-pull effect, by using ...

متن کامل

Utility of a single-stage isoproterenol tilt table test in adults: a randomized comparison with passive head-up tilt.

OBJECTIVES This study was conducted to develop a time-efficient tilt table test. BACKGROUND Current protocols of tilt table testing are quite time-consuming. This study was designed to assess the diagnostic value, tolerance and procedural time of a single-stage isoproterenol tilt table protocol. METHODS A single-stage isoproterenol tilt table test was compared with the passive tilt table te...

متن کامل

DI AGNOSTIC VAL UE OF SUBL INGUAL NITROGLYCERIN TILT TEST: COMPARISON WITH THE STANDARD ISOPROTERENOL TILT TEST

Sublingual nitroglycerin (TNG) has been introduced as a promising provocative agent for tilt table testing, but it has not been compared directly with the standard isoproterenol (ISO) infusion test previously. We tried to assess the diagnostic value and safety of TNG tilt testing as compared with ISO infusion in patients with unexplained syncope. TNG and ISO tilt tests were performed in tw...

متن کامل

Augmentation of the push-pull effect by terminal aortic occlusion during head-down tilt.

Tolerance to positive vertical acceleration (Gz) gravitational stress is reduced when positive Gz stress is preceded by exposure to hypogravity, which is called the "push-pull effect." The purpose of this study was to test the hypothesis that baroreceptor reflexes contribute to the push-pull effect by augmenting the magnitude of simulated hypogravity and thereby augmenting the stimulus to the b...

متن کامل

A new evaluation method for +Gz tolerance with loratadine by using a near-infrared spectroscopy

BACKGROUND Loratadine (Claritin), an over-the-counter antihistamine in U.S. and UK, is acceptable for use without adverse side effects by aircrew with mild or moderate allergic or other situations requiring an antihistamine. Although +Gz (head to foot direction) tolerance testing for aircrew with loratadine has not been documented in the published literature, it is commonly accepted that lorata...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indian journal of medical sciences

دوره 59 11  شماره 

صفحات  -

تاریخ انتشار 2005