Dynamic contour tonometry and goldman applanation tonometry in eyes with keratoconus.
نویسندگان
چکیده
PURPOSE The dynamic contour tonometer is a nonapplanation contact tonometer designed to be largely independent of the structural properties of the cornea. Theoretically, it may measure intraocular pressure most accurately in abnormally thinner corneas. This study compares intraocular pressure measurements by dynamic contour tonometry with Goldman applanation tonometry in eyes with normal corneas and eyes with advanced keratoconus. METHODS A comparative case series. Subjects underwent intraocular pressure measurements by dynamic contour tonometry, Goldman applanation tonometry, ultrasonic pachymetry, and slit scanning topography. EXCLUSION CRITERIA any ocular pathology other than keratoconus, previous corneal or refractive surgery, stromal scarring due to acute hydrops, or any other corneal opacities. RESULTS Ten patients with keratoconus were included in Group A, and 12 normal patients composed Group B according to the pre-established criteria. The mean Goldman tonometry measurement in group A was 10.3 +/- 1.8 mm Hg and group B was 14.3 +/- 0.75 mm Hg. (P = 0.024). In group A, the mean measurement with the dynamic contour tonometer was 14.6 +/- 2.09 mm Hg, and in group B, it was 17.4 +/- 3.1 mm Hg (P = 0.026). The difference between both methods of measurement in group A was statistically significant (P < 0.0002). CONCLUSION Intraocular pressure readings with dynamic contour tonometry in the keratoconus group were significantly higher than Goldman measurements and lower when compared to the control group. As there are no published manometric studies in eyes with keratoconus, these lower intra-ocular readings with the dynamic contour tonometry could be related to the discrepancy between the radius of corneal curvature and its tip, the significant thinning of the cornea, or other corneal biomechanical abnormalities related to advanced keratoconus.
منابع مشابه
Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus
PURPOSE To compare the intraocular pressure (IOP) measurements obtained with the rebound tonometry (RT), dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in keratoconic corneas and to investigate the effects of central corneal thickness (CCT) and corneal radius of curvature (CR) on IOP measurements. METHODS Sixty-three eyes of 63 keratoconus patients were enrolled in t...
متن کاملCorrelation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.
PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...
متن کاملReply to comment by De Bernardo and Rosa on "Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus".
Corresponding author at: Department of Medicine and Surgery, University of Salerno, Via Salvador Allende, 84081 Baronissi (SA), Italy. E-mail address: [email protected] (M. De Bernardo). https://doi.org/10.1016/j.optom.2017.10.001 1888-4296/ © 2017 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. This is an open access article under the CC BY-NC-ND license (http://c...
متن کاملIntraocular pressure profile during the modified diurnal tension curve using Goldman applanation tonometry and dynamic contour tonometry
The aim of this study was to compare the intraocular pressure (IOP) profile during the modified diurnal tension curve (mDTC) using Goldman applanation tonometry (GAT) and dynamic contour tonometry (DCT) in treated glaucomatous eyes. Eligible subjects were submitted to the mDTC using GAT and DCT in this sequence. IOP measurements were performed at 8 a.m., 10 a.m., 2 p.m., and 4 p.m.. Central cor...
متن کاملApplanation tonometry versus dynamic contour tonometry in eyes treated with latanoprost.
PURPOSE To examine the differences between Goldmann Applanation Tonometry (GAT) and Dynamic Contour Tonometry (DCT) associated with latanoprost use. METHODS Twenty-four eyes (of 24 patients) treated with latanoprost monotherapy (latanoprost group, LG), 11 eyes (of 11 patients) not receiving prostaglandin analogs (nonlatanoprost group, NLG), and 20 eyes of 20 nonglaucomatous patients (control ...