Radiometric Calibration Methods from Image Sequences

نویسندگان

  • Seon Joo Kim
  • Marc Pollefeys
چکیده

Seon Joo Kim: Radiometric Calibration Methods from Image Sequences. (Under the direction of Marc Pollefeys.) In many computer vision systems, an image of a scene is assumed to directly reflect the scene radiance. However, this is not the case for most cameras as the radiometric response function which is a mapping from the scene radiance to the image brightness is nonlinear. In addition, the exposure settings of the camera are adjusted (often in the auto-exposure mode) according to the dynamic range of the scene changing the appearance of the scene in the images. Vignetting effect which refers to the gradual fading-out of an image at points near its periphery also contributes in changing the scene appearance in images. In this dissertation, I present several algorithms to compute the radiometric properties of a camera which enable us to find the relationship between the image brightness and the scene radiance. First, I introduce an algorithm to compute the vignetting function, the response function, and the exposure values that fully explain the radiometric image formation process from a set of images of a scene taken with different and unknown exposure values. One of the key features of the proposed method is that the movement of the camera is not limited when taking the pictures whereas most existing methods limit the motion of the camera. Then I present a joint feature tracking and radiometric calibration scheme which performs an integrated radiometric calibration in contrast to previous radiometric calibration techniques which require the correspondences as an input which leads to a chicken-and-egg problem as precise tracking requires accurate radiometric calibration. By combining both into an integrated approach we solve this chicken-and-egg problem. Finally, I propose a radiometric calibration method suited for a set of images of an outdoor scene taken at a regular interval over a period of time. This type of data is a challenging problem because the illumination for each image is changing causing the exposure of the camera to change and the conventional radiometric calibration framework cannot be used for this type of data. The proposed methods are applied

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-Orbit Radiometric Calibration for a Space-Borne Multi-Camera Mosaic Imaging Sensor

As the core and foundational technology, on-orbit radiometric calibration of a space-borne sensor is of great importance for quantitative remote sensing applications. As for the space-borne multi-camera mosaic imaging sensor, however, the currently available on-orbit radiometric calibration method cannot carry out the integrated processing of on-orbit absolute radiometric calibration and relati...

متن کامل

Optimal Radiometric Calibration for Camera-Display Communication

We present a novel method for communicating between a moving camera and an electronic display by embedding and recovering hidden, dynamic information within an image. A handheld camera pointed at the display can receive not only the display image, but also the underlying message. These active scenes are fundamentally different from traditional passive scenes like QR codes because image formatio...

متن کامل

Landsat-8 Operational Land Imager (OLI) Radiometric Performance On-Orbit

Expectations of the Operational Land Imager (OLI) radiometric performance onboard Landsat-8 have been met or exceeded. The calibration activities that occurred prior to launch provided calibration parameters that enabled ground processing to produce imagery that met most requirements when data were transmitted to the ground. Since launch, calibration updates have improved the image quality even...

متن کامل

Pleiades-hr Innovative Techniques for Radiometric Image Quality Commissioning

The first Pleiades-HR satellite, part of a constellation of two, has been launched on December 17, 2011. This satellite produces high resolution optical images. In order to achieve good image quality, Pleiades-HR should first undergo an important 6 month commissioning phase period. This phase consists in calibrating and assessing the radiometric and geometric image quality to offer the best ima...

متن کامل

A Novel Approach for the Radiometric Correction of Airborne Hyperspectral Image Data

Hyperspectral imaging is increasingly used in various environmental measurement applications. Airborne hyperspectral sensors enables ground sampling distances (GSD) below 1 meter with high spectral resolution. In order to utilize this data in quantitative remote sensing applications, an accurate radiometric correction of the imagery has to be performed. In this article we present a radiometric ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008