Rapid detection of bacterial endotoxins in drinking water and renovated wastewater.

نویسندگان

  • J H Jorgensen
  • J C Lee
  • H R Pahren
چکیده

A pilot study was conducted to determine the feasibility of using the Limulus endotoxin assay to detect endotoxins in potable waters and from reclaimed advanced waste treatment (AWT) plant effluents. Water samples were tested using both Limulus lysates prepared in our laboratory and a commercial product, Difco Pyrotest. The Limulus assay procedure was easily adapted to the testing of water samples for endotoxin. Measured endotoxin concentrations varied from 0.78 ng/ml to 1,250 ng/ml. Levels of endotoxin were not predictable based on whether the water was drinking water or AWT water, i.e., some AWT water samples had less endotoxin activity than some samples of drinking water, and some AWT waters had greater endotoxin activity than drinking water. Only three of the water samples tested were free of any detectable endotoxin. Breakpoint chlorination procedures seemed to reduce measurable endotoxin content, whereas passage through activated carbon columns was associated with greater final endotoxin concentrations in test waters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Limulus assay, standard plate count, and total coliform count for microbiological assessment of renovated wastewater.

The Limulus endotoxin assay was compared to the standard plate count and total coliform count for assessment of the bacteriological quality of reclaimed wastewater. A total of 48 water samples from an advanced waste treatment plant in Dallas, Tex. were examined by the three techniques. Limulus assays were technically simpler to perform and provided results much sooner than conventional culture ...

متن کامل

بررسی میزان اندوتوکسین و کاهش سطح آن طی روش های تصفیه در یک تصفیه خانه آب آشامیدنی در شهر تهران

Background and purpose: Access to safe drinking water is of the utmost importance in public health around the world. Presence of contaminants, such as secondary bacterial growth and endotoxins could reduce the quality of water resources. This study aimed at investigating the occurrence, seasonal variation, and removal of endotoxins in a conventional water treatment plant (WTP) in Tehran, Iran. ...

متن کامل

Rapid detection of the most important pathogenic microorganisms in water and Food by (Chromogenic media)

Abstract Background and Objectives: Chromogenic media are the newest methods applied for rapid detection of pathogenic microorganisms in drinking water and food from 1998-2008. These Specific media contained the compounds acting as a substrate for microbial enzymes and, according to the type of enzyme, produce specific color. The aim of this study was to introduce the chromogenic media as a pow...

متن کامل

Point-of-care detection of Escherichia coli O157:H7 in water using AuNPs-based aptasensor

Objective(s): Access to safe drinking and irrigation water has always been one of the major human concerns worldwide. Thus, rapid, sensitive, and inexpensive approaches for pathogenic bacteria detection, such as Escherichia coli O157:H7 (EHEC) that can induce important infectious diseases, are highly on demand. Materials and Methods: In ...

متن کامل

Real-time determination of the efficacy of residual disinfection to limit wastewater contamination in a water distribution system using filtration-based luminescence.

Water distribution systems can be vulnerable to microbial contamination through cross-connections, wastewater backflow, the intrusion of soiled water after a loss of pressure resulting from an electricity blackout, natural disaster, or intentional contamination of the system in a bioterrrorism event. The most urgent matter a water treatment utility would face in this situation is detecting the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 32 3  شماره 

صفحات  -

تاریخ انتشار 1976