Identification and Characterization of an Oxidative Degradation Product of Fexofenadine, Development and Validation of a Stability-Indicating RP-UPLC Method for the Estimation of Process Related Impurities and Degradation Products of Fexofenadine in Pharmaceutical Formulations

نویسندگان

  • Bhupendrasinh Vaghela
  • Surendra Singh Rao
  • Annarapu Malleshwar Reddy
  • Panuganti Venkatesh
  • Navneet Kumar
چکیده

A novel stability-indicating gradient RP-UPLC method was developed for the quantitative determination of process related impurities and forced degradation products of fexofenadine HCl in pharmaceutical formulations. The method was developed by using Waters Aquity BEH C18 (100 mm x 2.1 mm) 1.7 μm column with mobile phase containing a gradient mixture of solvent A (0.05% triethyl amine, pH adjusted to 7.0 with ortho-phosphoric acid) and B (10:90 v/v mixture of water and acetonitrile). The flow rate of mobile phase was 0.4 mL/min with column temperature of 30°C and detection wavelength at 220nm. Fexofenadine HCl was subjected to the stress conditions including oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Fexofenadine HCl was found to degrade significantly in oxidative stress conditions, and degradation product was identified and characterized by ESI-MS/MS, (1)H and (13)C NMR spectroscopic method as the N-oxide 2-[4-(1-hydroxy-4-{4-[hydroxy(diphenyl)methyl]-1-oxido-piperidin-1-yl}butyl)phenyl]-2-methylpropanoic acid. The degradation products were well resolved from fexofenadine and its impurities. The mass balance was found to be satisfactory in all the stress conditions, thus proving the stability-indicating capability of the method. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection and quantification, accuracy, precision and robustness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability-indicating UFLC method for uncoupling and estimation of impurities in clopidogrel, aspirin and omeprazole in their tablet dosage form using PDA detection

In this paper a fast and novel stability-indicating ultra fast LC method for separation and estimation of impurities in clopidogrel and aspirin in their combined tablet dosage form and omeprazole was developed. The separation of USP related substances of clopidogrel (A, B and C), aspirin (D), omeprazole (A, B and C) and few other unknown impurities was detected by using ultra fast liquid chroma...

متن کامل

Development and Validation of a Stability-Indicating RP-UPLC Method for Determination of Rosuvastatin and Related Substances in Pharmaceutical Dosage Form

A stability-indicating reversed phase ultra performance liquid chromatographic (RP-UPLC) method was developed for the determination of related substances in rosuvastatin calcium (ROSV) tablet dosage form. The chromatographic separation was achieved on an Acquity BEH C18 (100 mm × 2.1 mm, 1.7 μm) column with mobile phase containing a gradient mixture of solvent-A (0.1% trifluoroacetic acid) and ...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

Rapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method

An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 80  شماره 

صفحات  -

تاریخ انتشار 2012