A Novel Attempt to Standardize Results of CFD Simulations Basing on Spatial Configuration of Aortic Stent-Grafts
نویسندگان
چکیده
Currently, studies connected with Computational Fluid Dynamic (CFD) techniques focus on assessing hemodynamic of blood flow in vessels in different conditions e.g. after stent-graft's placement. The paper propose a novel method of standardization of results obtained from calculations of stent-grafts' "pushing forces" (cumulative WSS--Wall Shear Stress), and describes its usefulness in diagnostic process. AngioCT data from 27 patients were used to reconstruct 3D geometries of stent-grafts which next were used to create respective reference cylinders. We made an assumption that both the side surface and the height of a stent-graft and a reference cylinder were equal. The proposed algorithm in conjunction with a stent-graft "pushing forces" on an implant wall, allowed us to determine which spatial configuration of a stent-graft predispose to the higher risk of its migration. For stent-grafts close to cylindrical shape (shape factor φ close to 1) WSS value was about 267 Pa, while for stent-grafts different from cylindrical shape (φ close to 2) WSS value was about 635 Pa. It was also noticed that deformation in the stent-graft's bifurcation part impaired blood flow hemodynamic. Concluding the proposed algorithm of standardization proved its usefulness in estimating the WSS values that may be useful in diagnostic process. Angular bends or tortuosity in bifurcations of an aortic implant should be considered in further studies of estimation of the risk of implantation failure.
منابع مشابه
A new approach for the pre-clinical optimization of a spatial configuration of bifurcated endovascular prosthesis placed in abdominal aortic aneurysms
Complexity of the spatial configuration of an aortic implant with bifurcation in the distal part is related to changes in blood hemodynamic in the area of bifurcation which may disturb blood flow and lead to thrombus formation. This study was designed to characterize parameters which define spatial configuration of an aortic implant for which the risk of thrombus formation is the smallest. We u...
متن کاملThermo-mechanical behavior of shape memory alloy made stent- graft by multi-plane model
Constitutive law for shape-memory alloys subjected to multi-axial loading, which is based on a semi-micromechanical integrated multi-plane model capable of internal mechanism observations, is generally not available in the literature. The presented numerical results show significant variations in the mechanical response along the multi loading axes. These are attributed to changes in the marten...
متن کاملA New Investigation on Tunnel Pool Fire Phenomenon Using CFD Technique
In this study, the amount of generated pool fire, as a result of the release of chemicals in the case of an accident in tunnels, was simulated and the results were compared to the experimental data. At first, various amounts of spatial resolution (R*) were considered to compare the existing experimental data at different heights at the upstream, downstream and above the pool fire...
متن کاملHemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm
This study investigates the effect of a novel flow remodeling stent graft (FRSG) on the hemodynamic characteristics in highly angulated abdominal aortic aneurysm based on computational fluid dynamics (CFD) approach. An idealized aortic aneurysm with varying aortic neck angulations was constructed and CFD simulations were performed on nonstented models and stented models with FRSG. The influence...
متن کاملSafety and Feasibility Study of a Novel Stent-Graft for Thoracic Endovascular Aortic Repair: a Canine Model Experiment
OBJECTIVE To evaluate the safety and feasibility of a novel stent-graft for thoracic endovascular aortic repair (TEVAR) in a canine model, 9 adult hybrid dogs were used for the experiment. METHODS All animals were implanted with a novel thoracic aortic stent-graft via femoral artery. Blood sample was collected at pre-operation and 1, 2, 4, 8 and 12 weeks after implantation for hematological e...
متن کامل