The treatment of uncoated and titanium nitride-coated abutments with different instruments.
نویسندگان
چکیده
PURPOSE The aim of this in vitro study of titanium abutments was to investigate the extent of treatment traces, the roughness depth, and the quantity of titanium or, in the case of coated abutments, titanium nitride (TiN) removed from the surface after treatment with various instruments. MATERIALS AND METHODS Eleven uncoated, mechanically smoothed abutments and 11 TiN-coated abutments were used. The abutments were treated with titanium, steel, and plastic curettes; a rubber cup; an ultrasonic scaler with a steel tip; and an air scaler and cleaning powder. There were two 2 x 2-mm test fields on each abutment; each was subjected to standardized treatment with an instrument. The untreated surfaces of each abutment served as controls. The roughness depth (Rz) and profile height of treated and untreated surfaces were measured with a profilometer; profile height served as a basis for determining the amount of substance removed by treatment. The treatment traces were analyzed by scanning electron microscopy and light microscopy. RESULTS Both the ultrasonic scaler and the steel and titanium curettes left pronounced traces on the uncoated abutments and increased Rz. Substantial substance removal was recorded following the use of the ultrasonic scaler (17.57 +/- 2.87 microm) and the steel curettes (8.48 +/- 2.81 microm) on the uncoated abutments. In tests of the coated abutments, measurable substance removal (4.80 +/- 0.99 microm) and increased roughness depth were noted only with use of the steel curettes. The treatment traces left by the other instruments were distinctly less pronounced than on the uncoated abutments. Light microscopy revealed detachment of the TiN coating after use of the ultrasonic scaler, titanium curettes, and steel curettes. Slight to moderate treatment traces were recorded after use of the rubber cup; no substance removal was observed. On the TiN-coated abutments, only slight treatment traces, if any, were recorded, and there was no substance removal. A planing effect (ie, an Rz decrease of 66.4%) was observed. The plastic curette and the air scaler caused no damage to the titanium or TiN surfaces. DISCUSSION AND CONCLUSION The TiN-coated abutments displayed fewer treatment traces, less roughness depth, and less substance removal after being treated with various instruments. Two concerns, however, are the detachment of the coating after only few actions with steel and titanium curettes or with an ultrasonic scaler with steel tip, and the greater initial roughness depth of coated implants.
منابع مشابه
Titanium Nitride and Nitrogen Ion Implanted Coated Dental Materials
Titanium nitride and/or nitrogen ion implanted coated dental materials have been investigated since the mid-1980s and considered in various applications in dentistry such as implants, abutments, orthodontic wires, endodontic files, periodontal/oral hygiene instruments, and casting alloys for fixed restorations. Multiple methodologies have been employed to create the coatings, but detailed struc...
متن کاملExperimental Analysis of Cryogenic Treatment on Coated Tungsten Carbide Inserts in Turning
This research work presents the results of an experimental investigation of cryogenically treated, coated and uncoated tungsten carbide cutting tool inserts in turning of AISI 1040 steel. Three different tungsten carbide inserts coated with aluminum chromium nitride (AlCrN), titanium nitride (TiN) and uncoated WC were taken and treated cryogenically. Experiments were performed to evaluate the c...
متن کاملOsseointegration of Ti6Al4V alloy implants coated with titanium nitride by a new method.
Coating titanium alloy implants with titanium nitride (TiN) by the method of Powder Immersion Reaction Assisted Coating (PIRAC) produces a stable layer on their surface. We have examined the ability of the new TiN coating to undergo osseointegration. We implanted TiN-coated and uncoated Ti6Al4V alloy pins into the femora of six-month-old female Wistar rats. SEM after two months showed a bone co...
متن کاملEffect of Thermochemical Treatment on The Structure, Hardness and Wear Behavior of Electrolss Ni-P Coated 4140 Steel
In the present stady, thermochemical treatment in H2/NH3 atmosphere was used as a post-treatment for electroless Ni-P coatings on the AISI 4140 steel substrates. High phosphorus (9%) coatings with thicknesses of 2, 24 and 48 m were applied and the effects of the thermochemical treatment on the morphology, structural changes, roughness, hardness and wear resistance of coatings were studied b...
متن کاملEffect of Thermochemical Treatment on The Structure, Hardness and Wear Behavior of Electrolss Ni-P Coated 4140 Steel
In the present stady, thermochemical treatment in H2/NH3 atmosphere was used as a post-treatment for electroless Ni-P coatings on the AISI 4140 steel substrates. High phosphorus (9%) coatings with thicknesses of 2, 24 and 48 m were applied and the effects of the thermochemical treatment on the morphology, structural changes, roughness, hardness 

and wear resistance of coatings were studi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 19 2 شماره
صفحات -
تاریخ انتشار 2004