Towards a complete coil array.

نویسنده

  • Zhiyue J Wang
چکیده

A complete RF coil system, as has been previously defined, is capable of generating any steady-state RF field, at the MR frequency, that is compatible with Maxwell's equations. A coil system is complete if it is capable of generating all basis vector fields in the multipole expansion of the electromagnetic fields. A complete coil system has the potential to reach the ultimate intrinsic signal-to-noise as an MRI receiver coil. It also offers maximum flexibility in tailoring the spatial RF field distribution as an excitation coil. Here, computer simulations have been performed on array coils employing composite coil elements, assuming the current loops are small and can be approximated by magnetic dipoles. We demonstrate that a coil array can be configured to approximate a truncated complete array coil and to generate the basis magnetic vector fields up to certain orders in the multipole expansion of the electromagnetic fields.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Cardiff Mk2b MIT head array: optimising the coil configuration

A hemispherical MIT helmet coil array for imaging cerebral haemorrhage has been designed using a realistic 12-tissue finite-difference model of the head including a large peripheral haemorrhage (volume 49 ml). The coil array was first optimised by reaching a compromise between the quality of the reconstructed images and the financial cost of the digital detection system. The practical implement...

متن کامل

In order to enable single echo acquisition imaging at a resolution of 64x256, a receiver system and array capable of simultaneous and independent detection of a single echo

1181 Abstract-Parallel imaging methods such as SMASH and SENSE reduce imaging time by using receiver coil sensitivity patterns to reduce requirements for gradient based image localization. This paper describes the first use of a coil array to completely eliminate gradient phase encoding. By using a 64 element planar array and a custom built 64 channel receiver system, 64x256 resolution images w...

متن کامل

RF transparent array for testing multi-channel transmit systems

Figure 3: Complete 8-channel transmit array in acrylic former Figure 4: Gradient echo images (TR=250 ms) of the individual coil elements shown in successive order, starting with the bottom element and working counter clockwise. There is no evidence of coupling with the body coil. The images were acquired using commercial power amplifiers and the conversion modules. RF transparent array for test...

متن کامل

Hole-Slotted Phased Array at 7 Tesla

Introduction The development of RF coils is always focused towards increasing SNR and optimizing the RF penetration into the sample. Multi channel receiver arrays have been shown to increase the SNR and/or the speed (if combined with parallel imaging) in clinical and animal MRI studies [1]. Array coils for high fields are usually based on simple loops and are mostly used in rat imaging studies ...

متن کامل

Development of a Receiver Coil Array for 2D Accelerated Imaging of the Complete Neurovascular System

Introduction Two-dimensional accelerated imaging [1] with acceleration factors as high as R = 8 has been applied successfully in contrastenhanced MR angiography (CE-MRA) of the brain [2, 3] and calves [4]. A key element of this implementation has been the use of multielement receiver coils which are designed for the targeted anatomic region. Multi-element coils for brain MRI are available on co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 26 9  شماره 

صفحات  -

تاریخ انتشار 2008