Variability of subjective classifications of corneal topography maps from LASIK candidates.

نویسندگان

  • Isaac C Ramos
  • Rosane Correa
  • Frederico P Guerra
  • William Trattler
  • Michael W Belin
  • Stephen D Klyce
  • Bruno M Fontes
  • Paulo Schor
  • Michael K Smolek
  • Daniel G Dawson
  • Maria Regina Chalita
  • Jorge O Cazal
  • Milton Ruiz
  • J Bradley Randleman
  • Renato Ambrósio
چکیده

PURPOSE To evaluate the variability of subjective corneal topography map classification between different experienced examiners and the impact of changing from an absolute to a normative scale on the classifications. METHODS Preoperative axial curvature maps using Scheimpflug imaging obtained with the Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany) and clinical parameters were sent to 11 corneal topography specialists for subjective classification according to the Ectasia Risk Scoring System. The study population included two groups: 11 eyes that developed ectasia after LASIK and 14 eyes that had successful and stable LASIK outcomes. Each case was first reviewed using the absolute scale masked to the patient group. After 3 months, the same cases were represented using a normative scale and reviewed again by the same examiners for new classifications masked to the patient group. RESULTS Using the absolute scale, 17 of 25 (68%) cases had variations on the classifications from 0 to 4 for the same eye across examiners, and the overall agreement with the mode was 60%. Using the normative scale, the classifications from 11 of 25 (44%) cases varied from 0 to 4 for the same eye across examiners, and the overall agreement with the mode was 61%. Eight examiners (73%) reported statistically higher scores (P < .05) when using the normative scale. Considering all 550 topographic analyses (25 cases, 11 examiners, and two scales), the same classification from the two scales was reported for 121 case pairs (44%). CONCLUSION There was significant inter-observer variability in the subjective classifications using the same scale, and significant intra-observer variability between scales. Changing from an absolute to a normative scale increased the scores on the classifications by the same examiner, but significant inter-observer variability in the subjective interpretation of the maps still persisted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser Eye Surgery from LASIK MD – Topography-Based Screening for Previous Laser In Situ Keratomileusis to correct Myopia (Abstract) Abstract Title: Topography-Based Screening for Previous Laser in Situ Keratomileusis for Myopia and Hyperopia

Title: Topography-Based Screening for Previous Laser in Situ Keratomileusis for Myopia and Hyperopia Purpose: To develop a screening tool based on corneal topography to detect previous myopic and hyperopic laser in situ keratomileusis (LASIK). Settings: Clinical data from three private clinics analyzed in a university setting. Methods: 476 topographies (Orbscan II, Bausch & Lomb) were randomly ...

متن کامل

Estimating variability in placido-based topographic systems.

PURPOSE To describe a new software tool for the detailed presentation of corneal topography measurements variability by means of color-coded maps. METHODS Software was developed in Visual Basic to analyze and process a series of 10 consecutive measurements obtained by a topographic system on calibration spheres, and individuals with emmetropic, low, high, and irregular astigmatic corneas. Cor...

متن کامل

Optical coherence tomography accurately measures corneal power change from laser refractive surgery.

PURPOSE To determine the ability of motion-corrected optical coherence tomography (OCT) to measure the corneal refractive power change due to LASIK. DESIGN Evaluation of a diagnostic test or technology in a cohort. SUBJECTS A total of 70 eyes from 37 subjects undergoing LASIK were measured preoperatively. A total of 39 eyes from 22 subjects were measured postoperatively and completed the st...

متن کامل

Optical response to LASIK surgery for myopia from total and corneal aberration measurements.

PURPOSE To evaluate the optical aberrations induced by LASIK refractive surgery for myopia on the anterior surface of the cornea and the entire optical system of the eye. METHODS Total and corneal aberrations were measured in a group of 14 eyes (preoperative myopia ranging from -2.5 to -13 D) before and after LASIK surgery. Total aberrations were measured using a laser ray-tracing technique. ...

متن کامل

Ectasia risk factors in refractive surgery.

This review outlines risk factors of post-laser in situ keratomileusis (LASIK) ectasia that can be detected preoperatively and presents a new metric to be considered in the detection of ectasia risk. Relevant factors in refractive surgery screening include the analysis of intrinsic biomechanical properties (information obtained from corneal topography/tomography and patient's age), as well as t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 29 11  شماره 

صفحات  -

تاریخ انتشار 2013