In vivo performance of melimine as an antimicrobial coating for contact lenses in models of CLARE and CLPU.

نویسندگان

  • Nerida Cole
  • Emma B H Hume
  • Ajay K Vijay
  • Padmaja Sankaridurg
  • Naresh Kumar
  • Mark D P Willcox
چکیده

PURPOSE One strategy to minimize bacteria-associated adverse responses such as microbial keratitis, contact lens-induced acute red eye (CLARE), and contact lens induced peripheral ulcers (CLPUs) that occur with contact lens wear is the development of an antimicrobial or antiadhesive contact lens. Cationic peptides represent a novel approach for the development of antimicrobial lenses. METHODS A novel cationic peptide, melimine, was covalently incorporated into silicone hydrogel lenses. Confirmation tests to determine the presence of peptide and anti-microbial activity were performed. Cationic lenses were then tested for their ability to prevent CLPU in the Staphylococcus aureus rabbit model and CLARE in the Pseudomonas aeruginosa guinea pig model. RESULTS In the rabbit model of CLPU, melimine-coated lenses resulted in significant reductions in ocular symptom scores and in the extent of corneal infiltration (P < 0.05). Evaluation of the performance of melimine lenses in the CLARE model showed significant improvement in all ocular response parameters measured, including the percentage of eyes with corneal infiltrates, compared with those observed in the eyes fitted with the control lens (P < or = 0.05). CONCLUSIONS Cationic coating of contact lenses with the peptide melimine may represent a novel method of prevention of bacterial growth on contact lenses and consequently result in reduction of the incidence and severity of adverse responses due to Gram-positive and -negative bacteria during lens wear.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biocompatibility of antimicrobial melimine lenses: rabbit and human studies.

PURPOSE Covalent immobilization of antimicrobial peptide melimine onto contact lenses can produce broad-spectrum antimicrobial lenses. The purpose of this study was to investigate the performance of melimine-coated contact lenses in an animal model and human clinical trial. METHODS Melimine was covalently attached onto the surface of contact lenses via EDC (1-ethyl-3-[3-dimethylaminopropyl] c...

متن کامل

Effect of Low Energy Surface Vibration on the Anti-adhesive Properties of Multipurpose Solutions

Contact lenses are a successful form of vision correction. But their use has been associated with an increased risk of microbial keratitis (MK), contact lens related acute red eye (CLARE) as well as contact lens peripheral ulcer (CLPU) (Eltis, 2011). One of the main problems associated with contact lenses is microbial contamination of the lens surface. Microbial contamination further leads to t...

متن کامل

گزارش سه مورد کراتیت آکانتامبایی در یزد

Acanthamoeba keratitis is a vision- threatening infection and the most important risk factors are contact lenses Characteristic symptoms include disproportionately severe ocular pain, epithelial ulcer, ring stromal infiltrate and resistance to antimicrobial treatment. The aim is to report the first cases of Acanthamoeba keratitis in Yazd in a retrospective study confirmed on histopathological ...

متن کامل

A clinical decision support system for contact lens evaluation

Background: Contact lenses are transparent, thin plastic disks that cover the surface of the cornea. Appropriate lens prescription should be performed properly by an expert to provide better visual acuity and reduce side effects. The lens administration is a multi-stage, complex and time-consuming process involving many considerations. The purpose of this study was to develop a decision support...

متن کامل

The effect of polar copolymers in protein absorption on contact lenses on 2-Hydroxyethyl methacrylate(HEMA)

For the purpose of increasing the permeability to oxygen and equilibrium water content in contact lenses, polar copolymers with nonionic monomers such as 2-hydroxyethle methacrylate(HEMA) Is used. By adding the polar monomers to (HEMA), the permeability to oxygen and equilibrium with water content is increased and also the absorption of proteins on lens surface is changed. In this research, the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 51 1  شماره 

صفحات  -

تاریخ انتشار 2010