Inter-turn Fault Analysis of Synchronous Generator using Finite Element Method (FEM)

نویسندگان

  • B. Jagadeesh
  • Chandra Prasad
  • B. V. Sanker Ram
چکیده

A turn fault in the stator winding of a generator causes a large circulating current to flow in the shorted turns. If left undetected, turn faults can propagate, leading to phaseground or phase-phase faults. Incipient detection of turn’s faults is essential to avoid hazardous operating conditions and reduce down time. At present the synchronous generators are protected against almost all kind of faults using differential methods of protection. All kind of faults develops into inter winding fault by damaging inter winding insulation. So it is necessary to protect the synchronous generator from inter winding faults which represents the protection against all kind of faults. There are different method based techniques for analyzing generator incipient/inter turn faults on stator side. They are circuit based, field based, wavelet based, artificial intelligence based, fuzzy based, artificial neural networks based. Machine performance characteristics that could be monitored to diagnose the stator inter-turn fault in generator include line current, terminal voltage, torque pulsations, temperature rise due to excessive losses, shaft vibrations, air-gap flux and speed ripples. So in this we are developing a mathematical model or method based on online/offline condition monitoring system by analyzing various conditions and collecting various samples of voltage and current (i.e. normal and abnormal) for protection of generators against faults (i.e. means incipient/inter turn faults) on stator side. The main Objective is to develop a mathematical model or method based on online/offline condition monitoring system by analyzing various conditions (i.e. normal and abnormal) for protection of generators against faults (i.e. means incipient/inter turn faults)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Magnetic Flux Linkage Distribution in Salient-Pole Synchronous Generator with Different Kinds of Inter-Turn Winding Faults

A reliable and accurate diagnosis of inter-turn short circuit faults is a challenging problem in the area of fault diagnosis of electrical machines. The purpose of this challenge is to be more efficient in fault detection and to provide a reliable method with low-cost sensors and simple numerical algorithms which not only detect the occurrence of the fault, but also locate its position in the w...

متن کامل

Application of Radial Basis Neural Networks in Fault Diagnosis of Synchronous Generator

This paper presents the application of radial basis neural networks to the development of a novel method for the condition monitoring and fault diagnosis of synchronous generators. In the proposed scheme, flux linkage analysis is used to reach a decision. Probabilistic neural network (PNN) and discrete wavelet transform (DWT) are used in design of fault diagnosis system. PNN as main part of thi...

متن کامل

Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...

متن کامل

Design Optimization for Total Volume Reduction of Permanent Magnet Synchronous Generators

Permanent magnet synchronous generators (PMSGs) are novel generators which can be used in high-performance wind farms. High efficiency and flexibility in producing electricity from variable rotation make them good candidate for wind power applications. Furthermore, because these kinds of generators have no excitation winding, there is no copper loss on rotor; hence, they can operate at high pow...

متن کامل

Detection of Inter-turn Faults in Five-Phase Permanent Magnet Synchronous Motors

Five-phase permanent magnet synchronous motors (PMSMs) have inherent fault-tolerant capabilities. This paper analyzes the detection of inter-turn short circuit faults in five-phase PMSMs in their early stage, i.e. with only one turn in short circuit by means of the analysis of the stator currents and the zero-sequence voltage component (ZSVC) spectra. For this purpose, a parametric model of fiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013