Assessment of a continuous blood gas monitoring system in animals during circulatory stress

نویسندگان

  • Sandro Gelsomino
  • Roberto Lorusso
  • Ugolino Livi
  • Stefano Romagnoli
  • Salvatore Mario Romano
  • Rocco Carella
  • Fabiana Lucà
  • Giuseppe Billè
  • Francesco Matteucci
  • Attilio Renzulli
  • Gil Bolotin
  • Giuseppe De Cicco
  • Pierluigi Stefàno
  • Jos Maessen
  • Gian Franco Gensini
چکیده

BACKGROUND The study was aimed to determine the measurement accuracy of The CDI™ blood parameter monitoring system 500 (Terumo Cardiovascular Systems Corporation, Ann Arbor MI) in the real-time continuous measurement of arterial blood gases under different cardiocirculatory stress conditions METHODS Inotropic stimulation (Dobutamine 2.5 and 5 μg/kg/min), vasoconstriction (Arginine-vasopressin 4, 8 and 16 IU/h), hemorrhage (-10%, -20%, -35%, and -50% of the theoretical volemia), and volume resuscitation were induced in ten swine (57.4 ± 10.7 Kg).Intermittent blood gas assessments were carried out using a routine gas analyzer at any experimental phase and compared with values obtained at the same time settings during continuous monitoring with CDI™ 500 system. The Bland-Altman analysis was employed. RESULTS Bias and precision for pO2 were - 0.06 kPa and 0.22 kPa, respectively (r2 = 0.96); pCO2 - 0.02 kPa and 0.15 kPa, respectively; pH -0.001 and 0.01 units, respectively ( r2 = 0.96). The analysis showed very good agreement for SO2 (bias 0.04,precision 0.33, r2 = 0.95), Base excess (bias 0.04,precision 0.28, r2 = 0.98), HCO3 (bias 0.05,precision 0.62, r2 = 0.92),hemoglobin (bias 0.02,precision 0.23, r2 = 0.96) and K+ (bias 0.02, precision 0.27, r2 = 0.93). The sensor was reliable throughout the experiment during hemodynamic variations. CONCLUSIONS Continuous blood gas analysis with the CDI™ 500 system was reliable and it might represent a new useful tool to accurately and timely monitor gas exchange in critically ill patients. Nonetheless, our findings need to be confirmed by larger studies to prove its reliability in the clinical setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gelsomino 1 Assessment of a Continuous Blood Gas Monitoring System in Animals during Circulatory stress. Short Title: Continuous Blood Gas Monitoring

Introduction: The study was aimed to determine the measurement accuracy of The CDI TM blood parameter monitoring system 500 (Terumo Cardiovascular Systems Corporation, Ann Arbor MI) in the real-time continuous measurement of arterial blood gases under different cardiocirculatory stress conditions Methods: Inotropic stimulation (Dobutamine 2.5 and 5 μg/kg/min), vasoconstriction (Argininevasopres...

متن کامل

Design and Evaluation of a Pressure and Temperature Monitoring System for Pressure Ulcer Prevention

Introduction Pressure ulcers are tissue damages resulting from blood flow restriction, which occurs when the tissue is exposed to high pressure for a long period of time. These painful sores are common in patients and elderly, who spend extended periods of time in bed or wheelchair. In this study, a continuous pressure and temperature monitoring system was developed for pressure ulcer preventio...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Positive end-expiratory pressure during mechanical ventilation and respiratory support in newborns and children

Positive end-expiratory pressure (PEEP) is used during non-invasive and invasive ventilation of newborns, infants and children. PEEP improves gas exchange by increasing the functional residual capacity, reducing respiratory effort, lowering requirements for respiratory mixture oxygen, and enabling a decrease in the peak inspiratory pressure (PIP) without decreasing the mean airway pressure. Its...

متن کامل

Discontinuous monitoring of propofol concentrations in expired alveolar gas and in arterial and venous plasma during artificial ventilation.

BACKGROUND Analyzing propofol concentration in expired alveolar gas (cPA) may be considered as a convenient, noninvasive method to follow the propofol concentration in plasma (cPPL). In the current study, the authors established procedures to measure cPA and cPPL for the assessment of their relation in two animal models during anesthesia. METHODS Expired alveolar gas and mixed venous and arte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2011