Does Additional Aortic Procedure Carry a Higher Risk in Patients Undergoing Aortic Valve Replacement?

نویسندگان

  • Tae-Hun Kim
  • Kay-Hyun Park
  • Jae Suk Yoo
  • Jae Hang Lee
  • Cheong Lim
چکیده

BACKGROUND With growing attention to the aortopathy associated with aortic valve diseases, the number of candidates for accompanying ascending aorta and/or root replacement is increasing among the patients who require aortic valve replacement (AVR). However, such procedures have been considered more risky than AVR alone. This study aimed to compare the surgical outcome of isolated AVR and AVR combined with aortic procedures. MATERIALS AND METHODS A total of 86 patients who underwent elective AVR between 2004 and June 2010 were divided into two groups: complex AVR (n=50, AVR with ascending aorta replacement in 24 and the Bentall procedure in 26) and simple AVR (n=36). Preoperative characteristics, surgical data, intra- and postoperative allogenic blood transfusion requirement, the postoperative clinical course, and major complications were retrospectively reviewed and compared. RESULTS The preoperative mean logistic European System for Cardiac Operative Risk Evaluation (%) did not differ between the groups: 11.0±7.8% in the complex AVR group and 12.3±8.0% in the simple AVR group. Although complex AVR required longer cardiopulmonary bypass (152.4±52.6 minutes vs. 109.7±22.7 minutes, p=0.001), the quantity of allogenic blood products did not differ (13.4±14.7 units vs. 13.9±11.2 units). There was no mortality, mechanical circulatory support, stroke, or renal failure requiring hemodialysis/filtration. No difference was found in the incidence of bleeding (40% vs. 33.3%) which was defined as red blood cell transfusion ≥5 units, reoperation, or intentional delayed closure. The incidence of mediastinitis (2.0% vs. 0%), ventilator ≥24 hours (4.0% vs. 2.8%), atrial fibrillation (18.0% vs. 25.0%), mean intensive care unit stay (34.5 hours vs. 38.8 hours), and median hospital stay (8 days vs. 7 days) did not differ, either. CONCLUSION AVR combined with additional aortic or root replacement showed an excellent outcome and recovery course equivalent to that after isolated AVR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تعویض دریچه آئورت: مقایسه روش متداول و روش جدید

Background: The usage of pericardium of patient himself, for support of anastomosis lines may carry benefits in patients undergoing aortic valve replacement with pulmonary autograft (Ross). The aim of the present study was to compare the short term results of aortic valve replacement with pulmonary autograft with routine and offered methods. Methods: In a non-randomized clinical trial, 64 pati...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

Correlation Between Aortic Valve Sclerosis and Coronary Artery Disease: A Cross - Sectional Study

  Introduction: Aortic valve sclerosisis considered as a manifestation of coronary atherosclerosis. Recent studies demonstrated an association between aortic valve sclerosis and obstructive coronary artery disease. The purpose of this study was to evaluatethe correlation betweenaortic valve sclerosis andobstructive coronary artery disease and the extent of coronary artery disease in patients ho...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 45  شماره 

صفحات  -

تاریخ انتشار 2012