Cirrus high-definition optical coherence tomography compared with Stratus optical coherence tomography in glaucoma diagnosis.
نویسندگان
چکیده
PURPOSE To compare the retinal nerve fiber layer (RNFL) evaluation using Cirrus optical coherence tomography (OCT) and Stratus OCT in glaucoma diagnosis. METHODS One hundred thirty normal and 86 patients with glaucoma were included in this prospective study. The signal strengths of the OCTs were evaluated. The sensitivities and specificities of global RNFL average thickness were compared in the four quadrants and in each clock hour sector. Receiver operating characteristic (ROC) curves, areas under the ROC (AUC), and the likelihood ratio (LR) were plotted for RNFL thickness. Agreement between the OCTs was calculated by using the Bland-Altman method and kappa (kappa) coefficient. RESULTS Twenty-three percent of all cases examined with Stratus OCT and 1.9% examined with Cirrus OCT had a signal strength below 6 (P = 0.01). In cases with signal strengths > or =6, the mean signal strength was higher with Cirrus OCT than with Stratus OCT (P = 0.01). The RNFL measurements by Cirrus were thicker than those of Stratus OCT (P < 0.05). The AUCs were 0.829 for Stratus and 0.837 for Cirrus OCT (P = 0.706) for global RNFL average. LRs were similar in both OCTs in global RNFL classification but varied in quadrants. The widths of the limits of agreement varied between 42.16 and 97.79 microm. There was almost perfect agreement (kappa = 0.82) in the average RNFL classification. CONCLUSIONS Cirrus OCT has better scan quality than Stratus OCT, especially in glaucomatous eyes. In cases with good-quality scans, the sensitivity and specificity, and AUCs were similar. The best agreement was in the global average RNFL classification. The widths of limits of agreements exceed the limits of resolution of the OCTs.
منابع مشابه
Performance of time-domain and spectral-domain Optical Coherence Tomography for glaucoma screening
PURPOSE To investigate the measures of validity for selective or population screening of the time-domain Stratus and the spectral-domain Cirrus Optical Coherence Tomography (OCT) imaging techniques in a population-based sample and in clinical glaucoma patients at different stages of glaucoma. PATIENTS AND METHODS A random sample of 307 subjects living in two rural areas in southern Sweden, an...
متن کاملComparison of glaucoma diagnostic Capabilities of Cirrus HD and Stratus optical coherence tomography.
OBJECTIVE To compare the glaucoma diagnostic capabilities offered by Stratus and Cirrus spectral-domain optical coherence tomography (OCT). METHODS One hundred subjects with glaucoma and 74 healthy subjects were tested by Stratus and Cirrus OCT. Areas under the receiver operating characteristic curves (AUCs) of average, 4-quadrant, and 12-sector retinal nerve fiber layer thicknesses and sensi...
متن کاملSpectral-domain optical coherence tomography for detection of localized retinal nerve fiber layer defects in patients with open-angle glaucoma.
OBJECTIVE To evaluate and compare time-domain (Stratus) and spectral-domain (Cirrus; both Carl Zeiss Meditec, Dublin, California) optical coherence tomography (OCT) for the detection of localized retinal nerve fiber layer (RNFL) defects in patients with open-angle glaucoma. METHODS Patients with localized RNFL defects and age-matched normal control participants were consecutively enrolled fro...
متن کاملComparison of optic nerve head parameter measurements obtained by time-domain and spectral-domain optical coherence tomography.
PURPOSE To compare the measurements of the optic nerve head (ONH) parameters provided by time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT). METHODS Four ONH parameters were analyzed: optic disc area, rim area, cup-to-disc area ratio (CDR), and vertical cup-to-disc ratio (VCDR). Stratus OCT and Cirrus HD-OCT were used to obtain measurements by TD-OCT and SD-OCT, resp...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 51 1 شماره
صفحات -
تاریخ انتشار 2010