Digital image ratio: a new radiographic method for quantifying changes in alveolar bone. Part 1: Theory and methodology.
نویسندگان
چکیده
A new world, digital image ratio (DIR), has been developed for directly measuring changes in alveolar bone. The image on the computer monitor represents the relative mass change between two radiographs. Fourier filtering is used to reduce noise artefacts. This method is validated through an experiment with a step wedge. DIR needs only a preliminary calibration of the experimental conditions of operation and avoids tedious calibrations for each measurement as in the case of digital image substraction. Low-voltage X-ray techniques are suggested for long-term quantitative studies of patients to minimize irradiation doses.
منابع مشابه
Digital image ratio: a new radiographic method for quantifying changes in alveolar bone. Part II: Clinical application.
As reported in a previous paper (1) we have developed a new technique, Digital Image Ratio (DIR), which theoretically avoids some of the drawbacks of quantitative digital substraction radiography. DIR allows the direct computation and visualization of bone-mass-ratio changes. This second paper describes the use of DIR analysis to examine 20 sites in 8 patients undergoing regenerative periodonta...
متن کاملRadiographic comparison of the repaired bone in maxillary alveolar cleft of dog by tissue engineering and autogenous bone grafting techniques
BACKGROUND: Dental disease, trauma and maxillofacial surgeries can cause alveolar bone defects. Among different kinds of treatment, autogenous bone grafts is accepted as a golden standard. On the other hand, because of limitation of treatment with autogenous bone grafts, osteogenic cells derived from stem cells are suggested. OBJECTIVES: The aim of this study was to compare the mean density of ...
متن کاملارزیابی دقت دانسیتومتری تصاویر دیجیتال غیر مستقیم
Statement of Problem: One of the major goals, in most dental researches, is to measure bone destruction or deposition due to the progression or regression of disease. Failure of human eyes to detect minor radiographic density changes resulted in more accurate methods such as optical densitometry and direct or indirect digital densitometry.Purpose: The aim of this study was to determine the accu...
متن کاملA Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography
Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...
متن کاملبررسی و مقایسه دقت رادیوگرافی های پانورامیک، پری اپیکال و بایت وینگ در تعیین میزان تحلیل استخوان آلوئول در پریودنتیت
Introduction: The height of the alveolar bone, is normally maintained by equilibrium between bone formation and bone resorption, but in periodontal disease more destruction or lack of bone formation will reduce the alveolar bone height. However the radiography is important in diagnosis, treatment plan and detection of quality and quantity of the alveolar bone although the type of radiography is...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of periodontal research
دوره 31 3 شماره
صفحات -
تاریخ انتشار 1996